* Only available in selected markets
Abstract
The Lenovo ThinkSystem SR635 is a 1-socket 1U server that features the AMD EPYC 7002 "Rome" and AMD EPYC 7003 "Milan" families of processors. With up to 64 cores per processor and support for the PCIe 4.0 standard for I/O, the SR635 offers the ultimate in single-socket server performance in a space-saving 1U form factor.
This product guide provides essential pre-sales information to understand the ThinkSystem SR635 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR635 and consider its use in IT solutions.
Withdrawn: The SR635 is withdrawn from marketing.
How customers use SR635
Case Study: Pappaya Cloud
Building share in the multi-billion-dollar cloud market
To grow its managed cloud services business rapidly, Pappaya Cloud partnered with Lenovo TruScale Infrastructure as a Service (IaaS) to deploy a platform based on Lenovo ThinkSystem servers powered by AMD EPYC™ processors.
How customers use SR635
Case Study: Zdorovie Pharmacy
Scalable IT platform empowers pharmacy chain to open new stores and connect more people with care services.
How pharmacy chain Zdorovie used Lenovo ThinkSystem DE4000H Hybrid Storage and Lenovo ThinkSystem SR635 servers powered by 2nd Gen AMD EPYC™ processors to support the digital systems that underpin its fast-growing business—helping the organization to open new pharmacy locations and reach more people across Russia’s Southern Federal District.
How customers use SR635
Case Study: Supership
Powering advertising technology at scale to drive corporate expansion:
How Supership used Lenovo ThinkSystem SR635, powered by 2nd Gen AMD EPYC™ processors, to triple server density and support the growth of its advertising technology business.
How customers use SR635
Case Study: Earth Observation Data Centre
Accelerating analysis of satellite data to support flood warning systems and save lives:
How EODC Earth Observation Data Centre used Lenovo ThinkSystem SR635 servers, powered by AMD EPYC™ processors, to provide near real-time flood monitoring.
How customers use SR635
Case Study: Ministry of Healthcare of the Republic of Kazakhstan/iNOVA Tech
Leveraging AI to diagnose cancer up to 10x faster
To help accelerate breast cancer screening at 120 hospitals in Kazakhstan, iNOVA TECH deployed a hyperconverged infrastructure solution powered by 14 Lenovo ThinkAgile HX5520 nodes—enabling rapid, AI-powered processing of radiological images.
How customers use SR635
Case Study: StackPath
Bringing the cloud closer to users
Enabling customers with latency-sensitive workloads to host their applications at the edge, supported by Lenovo.
How customers use SR635
Case Study: University of Tartu
Driving HPC excellence
The HPC Center at the University of Tartu keeps Estonia at the forefront of HPC innovation with Lenovo ThinkSystem servers powered by dual AMD EPYC™ 7003 Series processors and Lenovo storage.
Walkthrough video with David Watts and Russ Resnick
Introduction
The Lenovo ThinkSystem SR635 is a 1-socket 1U server that features the AMD EPYC 7002 "Rome" and AMD EPYC 7003 "Milan" families of processors. With up to 64 cores per processor and support for the PCIe 4.0 standard for I/O, the SR635 offers the ultimate in single-socket server performance in a space-saving 1U form factor. With up to 128 PCIe lanes, the server is ideal for dense workloads that can take advantage of GPU processing and high-performance NVMe drives.
Suggested uses: AI Inference, VDI, OLTP, Analytics, HPC, software-defined storage
Did you know?
By using a high-performance server with only one processor installed, you can take advantage of lower software costs when the software licensing is using a per-socket model. In addition, The server offers onboard NVMe PCIe ports that allow direct connections to 16x NVMe SSDs, which frees up I/O slots and helps lower NVMe solution acquisition costs.
The SR635 has been designed to take advantage of the features of the EPYC 7002 and 7003 processors, such as the full performance of 280W 64-core processors, support for 3200 MHz memory and PCIe Gen 4.0 support. Competitive servers that are based on the older EPYC 7001 "Naples" designs may not be able to offer these performance features.
Key features
Combining performance and flexibility, the SR635 server is a great choice for enterprises of all sizes. The server offers a broad selection of drive and slot configurations and offers high performance features that industries such as finance, healthcare and telco need. Outstanding reliability, availability, and serviceability (RAS) and high-efficiency design can improve your business environment and can help save operational costs.
Scalability and performance
The SR635 offers numerous features to boost performance, improve scalability and reduce costs:
- Supports the AMD EPYC 7002 and EPYC 7003 families family of processors
- Supports processors with up to 64 cores and 128 threads, core speeds of up to 4.1 GHz, and TDP ratings of up to 280W.
- Support for up to 16 TruDDR4 memory DIMMs, with 8 memory channels and 2 DIMMs per channel. With 1 DIMM installed per channel (8 DIMMs total), memory operates at up to 3200 MHz. With 2 DIMMs per channel (16 DIMMs total), memory operating at up to 2933 MHz.
- Using 128GB DIMMs, the server supports up to 2TB of system memory.
- Supports up to three single-width GPUs, each up to 75W. A 3:1 ratio of GPUs to CPUs means substantial processing power is available with just one CPU.
- Supports up to 16x 2.5-inch hot-swap drive bays, by using combinations of front-accessible (up to 10 bays), mid-accessible (4 bays), and rear-accessible (2 bays).
- Supports four 3.5-inch drive bays for lower-cost high-capacity storage. 2.5-inch and 3.5-inch drive bays can be mixed in several combinations.
- Supports 16x NVMe drives without oversubscription of PCIe lanes (1:1 connectivity) and without the need for additional NVMe adapters. The use of NVMe drives maximizes drive I/O performance, in terms of throughput, bandwidth, and latency.
- Supports 12x SATA drives using the onboard SATA controller (no additional adapter needed), enabling lower cost, high capacity storage solution for cold storage workloads.
- Supports 12x SAS drives using a variety of support RAID controllers or SAS HBAs.
- Supports high-speed RAID controllers from Broadcom providing 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache and support for 16 drives on a single controller.
- Supports M.2 drives for convenient operating system boot functions or data storage. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for performance and reliability.
- The server has a dedicated industry-standard OCP 3.0 small form factor (SFF) slot, with a PCIe 4.0 x16 interface, supporting a variety of Ethernet network adapters. Simple-swap mechanism with thumbscrews and pull-tab enables tool-less installation and removal of the adapter. Supports shared BMC network sideband connectivity to enable out-of-band systems management.
- The server offers PCI Express 4.0 I/O expansion capabilities that doubles the theoretical maximum bandwidth of PCIe 3.0 (16GT/s in each direction for PCIe 4.0, compared to 8 GT/s with PCIe 3.0). A PCIe 4.0 x16 slot provides 64 GB/s bandwidth, enough to support a 400GbE network connection.
- A total of up to four PCIe 4.0 slots (3 with rear access, 1 internal for a RAID adapter) plus a slot dedicated to the OCP adapter.
Availability and serviceability
The SR635 provides many features to simplify serviceability and increase system uptime:
- The server uses ECC memory and supports memory RAS features including Single Device Data Correction (SDDC, also known as Chipkill), Patrol/Demand Scrubbing, DRAM Address Command Parity with Replay, and DRAM Uncorrected ECC Error Retry.
- The server offers hot-swap drives, supporting RAID redundancy for data protection and greater system uptime.
- The M.2 SATA RAID Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
- The server has up to two hot-swap redundant power supplies and seven hot-swap redundant fans to provide availability for business-critical applications.
- The power-source-independent light path diagnostics uses LEDs to lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
- Solid-state drives (SSDs) offer more reliability than traditional mechanical HDDs for greater uptime.
- The built-in ASPEED AST2500 baseboard management controller (BMC) continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
- Proactive Platform Alerts: Voltage regulators, memory, fans, power supplies, server ambient and subcomponent temperatures. Alerts can be surfaced through the BMC to managers such as Lenovo XClarity Administrator. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
- Web-based ThinkSystem System Manager (TSM) provides remote access to the BMC for remote management.
- Lenovo XClarity Provisioning Manager Lite (LXPM Lite) tool can be used to install an operating system on the server and perform system diagnostics.
- Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.
Manageability and security
Systems management features simplify local and remote management of the SR635:
- Supports Lenovo XClarity Provisioning Manager Lite (LXPM Lite) for system setup and firmware upgrades.
- An integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
- Support for industry standard management protocols, IPMI 2.0, SNMP 3.0, Redfish REST API, serial console via IPMI
- An integrated hardware Trusted Platform Module (TPM) supporting TPM 2.0 enables advanced cryptographic functionality, such as digital signatures and remote attestation.
- Administrator and power-on passwords help protect from unauthorized access to the server.
- Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and integrates with Redfish-based applications to provide automated controls to lower energy costs.
- Supports AMD Secure Root-of-Trust, Secure Run and Secure Move features to minimize potential attacks and protect data as the OS is booted, as applications are run and as applications are migrated from server to server.
- Supports Secure Boot to ensure only a digitally signed operating system can be used.
- Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
Energy efficiency
The SR635 offers the following energy-efficiency features to save energy, reduce operational costs, and increase energy availability:
- Energy-efficient planar components help lower operational costs.
- High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications
- Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
- Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs.
- The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system and thus keeping your system cooler.
- Optional Lenovo XClarity Energy Manager provides advanced data center power notification and analysis to help achieve lower heat output and reduced cooling needs.
Components and connectors
The following figure shows the front of the server.
The following figure shows the components visible from the rear of the server. As shown, there are three different configurations available
System architecture
Standard specifications
The following table lists the standard specifications.
Components | Specification |
---|---|
Machine types | 7Y98 - 1 year warranty 7Y99 - 3 year warranty |
Form factor | 1U rack. |
Processor | One AMD EPYC 7002 Series processor (formerly codenamed "Rome") or AMD EPYC 7003 Series processors (formerly codenamed "Milan"). Supports processors up to 64 cores, core speeds of up to 4.1 GHz, and TDP ratings of up to 280W. |
Memory | 16 DIMM slots. The processor has 8 memory channels, with 2 DIMMs per channel. Lenovo TruDDR4 RDIMMs are supported. DIMMs are available in two speeds: 3200 MHz and 2933 MHz. With 3200 MHz memory, the server supports a 3200 MHz memory bus speed at 1 DIMM per channel (DPC) and 2933 MHz at 2 DPC. With 2933 MHz memory, the server supports a 2933 MHz memory bus speed at both 1 and 2 DPC. |
Memory maximum | Up to 2TB with 16x 128GB 3DS RDIMMs |
Persistent memory | Not supported. |
Memory protection | ECC, SDDC, Patrol/Demand Scrubbing, DRAM Address Command Parity with Replay, DRAM Uncorrected ECC Error Retry, Post Package Repair |
Disk drive bays |
Up to 4x 3.5-inch or 16x 2.5-inch hot-swap drive bays:
See Supported drive bay combinations for details. AnyBay bays support SAS, SATA or NVMe drives. NVMe bays only support NVMe drives. Both mid and rear drive bays can be used in conjunction with 2.5-inch front drive bays. Mid bays are hot-swap drive bays and are accessible by removing the top cover of the server. The server supports up to 16x NVMe drives (10 front, 4 mid, 2 rear) all with direct connections (no oversubscription). |
Maximum internal storage |
|
Storage controller |
|
Optical drive bays | No internal optical drive. |
Tape drive bays | No internal backup drive. |
Network interfaces | Dedicated OCP 3.0 SFF slot with PCIe 4.0 x16 host interface. Supports a variety of 2-port and 4-port adapters with 1GbE, 10GbE and 25GbE network connectivity. One port can optionally be shared with the ASPEED management processor for Wake-on-LAN and NC-SI support. |
PCI Expansion slots |
A total of up to 4 PCIe 4.0 slots (3 with rear access, 1 internal for a RAID adapter) plus a slot dedicated to the OCP adapter. Slot availability is based on riser selection. Three choices for rear-access slots:
Optionally, an additional internal PCIe 4.0 x8 low-profile slot for al internal drive controller. |
Ports |
Front: Two USB 3.1 G1 (5 Gb/s) ports, optional VGA port. Rear: USB 3.1 G1 (5 Gb/s) ports, one VGA video port, one DB-9 serial port, and one RJ-45 1GbE systems management port. Internal: Optional M.2 module supporting up to two M.2 drives (for OS boot and drive storage support; not available in all configurations). |
Cooling | Six or seven N+1 redundant dual-rotor hot swap 40 mm fans, configuration dependent. One fan integrated in each power supply. |
Power supply | Up to two hot-swap redundant AC power supplies (all 80 PLUS Platinum certification): 550 W, 750 W, 1100 W and 1600 W AC options, supporting 220 V AC. 550 W, 750 W and 1100 W options also support 110V input supply. In China only, all power supply options support 240 V DC. Also available is a 1100W power supply with a -48V DC input. |
Video | Onboard graphics with 512 MB memory with 2D hardware accelerator, integrated into the ASPEED AST2500 BMC management processor. Maximum resolution is 1920x1200 at 60Hz, 32bpp |
Hot-swap parts | Drives, power supplies, and fans. |
Systems management | ASPEED AST2500 embedded management processor, XClarity Provisioning Manager Lite (LXPM Lite) for system setup and firmware upgrades. XClarity Administrator centralized infrastructure management, and XClarity Energy Manager centralized server power management. Light path diagnostics for local failure detection and reporting. |
Security features | Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 2.0. In China only, optional Nationz TPM 2.0. Optional lockable front security bezel. Optional chassis intrusion switch. |
Operating systems supported | Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics. |
Limited warranty | Three-year or one-year (model dependent) customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD). |
Service and support | Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications. |
Dimensions | Width: 440 mm (17.3 in.), height: 43 mm (1.7 in.), depth: 755 mm (29.7 in.). See Physical and electrical specifications for details. |
Weight | Maximum: 19.2 kg (42.3 lb) |
Models
ThinkSystem SR635 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).
Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SR635 as listed in the columns in the following table:
- General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
- AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.
Preconfigured server models may also be available for the SR635, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.
The following table lists the base CTO models of the ThinkSystem SR635 server.
Machine Type/Model General purpose |
Machine Type/Model for AI and HPC |
Description |
---|---|---|
7Y99CTO1WW | 7Y99CTOLWW | ThinkSystem SR635 – 3-year warranty |
7Y98CTO1WW | 7Y98CTOLWW | ThinkSystem SR635 – 1-year warranty |
Models of the SR635 are defined based on whether the server has 2.5-inch drive bays at the front (called the 10x 2.5" chassis or simply the 2.5-inch chassis) or whether it has 3.5-inch drive bays at the front (called the 4x 3.5" chassis or simply the 3.5-inch chassis). For models, the feature codes for these chassis bases are as listed in the following table.
Feature code | Description |
---|---|
B5VL | ThinkSystem SR635 10x2.5" Chassis |
B5VM | ThinkSystem SR635 4x3.5" Chassis |
The following tables list the available models, grouped by region.
- Models for Australia and New Zealand
- Models for South East Asian countries (ASEAN)
- Models for Brazil
- Models for EMEA countries
- Models for Hong Kong, Taiwan, Korea (HTK)
- Models for India
- Models for Japan
- Models for Latin American countries (except Brazil)
- Models for USA and Canada
Refer to the Specifications section for information about standard features of the server.
Models for Australia and New Zealand
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
TopSeller models with a 3-year model (machine type 7Y99) | ||||||||||
7Y99A029AU | 7232P 8C 120W 3.1G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A02CAU | 7232P 8C 120W 3.1G | 1x 32GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A02JAU | 7232P 8C 120W 3.1G | 1x 16GB 3200 | 530-8i | 8x 2.5" SAS Open bay | Open | Open / 1 | 1x 750W HS (Y) | Yes | 7x Std | Fric |
7Y99A02KAU | 7232P 8C 120W 3.1G | 1x 16GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A02LAU | 7252 8C 120W 3.1G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A02GAU | 7262 8C 155W 3.2G | 1x 32GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A02QAU | 7262 8C 155W 3.2G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | Open / 1 | 1x 750W HS (Y) | Yes | 7x Std | Fric |
7Y99A02AAU | 7282 16C 120W 2.4G | 1x 32GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A02BAU | 7282 16C 120W 2.4G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A02FAU | 7282 16C 120W 2.4G | 1x 32GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A02PAU | 7282 16C 120W 2.4G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | Open / 1 | 1x 750W HS (Y) | Yes | 7x Std | Fric |
7Y99A00XAU | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A02EAU | 7302P 16C 155W 3.0G | 1x 32GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A02NAU | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | Open / 1 | 1x 750W HS (Y) | Yes | 7x Std | Fric |
7Y99A014AU | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A02HAU | 7402P 24C 180W 2.8G | 1x 32GB 3200 | Onboard AHCI | 8x 2.5" SAS Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A02MAU | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | Open / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Fric |
7Y99A00UAU | 7502P 32C 180W 2.5G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A00WAU | 7702P 64C 200W 2.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for South East Asian countries (ASEAN)
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
TopSeller models with a 3-year model (machine type 7Y99) | ||||||||||
7Y99A00VSG | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A00QSG | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A00YSG | 7502P 32C 180W 2.5G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A00RSG | 7702P 64C 200W 2.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for Brazil
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
Standard models with a 3-year model (machine type 7Y99) | ||||||||||
7Y99A01GBR | 7262 8C 155W 3.2G | 1x 16GB 2933 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01HBR | 7302P 16C 155W 3.0G | 1x 16GB 2933 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01JBR | 7302P 16C 155W 3.0G | 1x 32GB 2933 | 730-8i 1GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01FBR | 7402P 24C 180W 2.8G | 1x 32GB 2933 | 730-8i 1GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for EMEA countries
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
Standard models with a 3-year model (machine type 7Y99) | ||||||||||
Models with third-generation AMD EPYC processors | ||||||||||
7Y99A032EA | 7313P 16C 155W 3.0G | 1x 32GB 3200 | 940-8i 4G | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A031EA | 7343 16C 190W 3.2G | 1x 32GB 3200 | 940-8i 4G | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Slide |
7Y99A030EA | 7453 28C 225W 2.8G | 1x 32GB 3200 | 940-8i 4G | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Slide |
7Y99A02ZEA | 7543P 32C 225W 2.8G | 1x 32GB 3200 | 940-8i 4G | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Slide |
7Y99A02YEA | 7713P 64C 225W 2.0G | 1x 32GB 3200 | 940-8i 4G | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Slide |
Models with second-generation AMD EPYC processors | ||||||||||
7Y99A020EA | 7232P 8C 120W 3.1G | 1x 32GB 2933 | 930-8i | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A021EA | 7232P 8C 120W 3.1G | 1x 32GB 2933 | Onboard AHCI | 4x 3.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 550W (Y) | Yes | 7x Std | Slide |
7Y99A00KEA | 7262 8C 155W 3.2G | 1x 32GB 3200 | Onboard AHCI | 10x 2.5" (6xSAS + 4xAny) Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A023EA | 7282 16C 120W 2.4G | 1x 32GB 2933 | Option | Optional 2.5" Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A00LEA | 7302P 16C 155W 3.0G | 1x 32GB 3200 | Onboard AHCI | 10x 2.5" (6xSAS + 4xAny) Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A00NEA | 7302P 16C 155W 3.0G | 1x 32GB 3200 | Onboard AHCI | 4x 3.5" SAS Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A022EA | 7302P 16C 155W 3.0G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide |
7Y99A01YEA | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Slide |
7Y99A00JEA | 7502P 32C 180W 2.5G | 1x 32GB 3200 | Onboard AHCI | 10x 2.5" (6xSAS + 4xAny) Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Perf | Slide |
7Y99A01ZEA | 7552 48C 200W 2.2G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | 3x LP x16 / 1 | 1x 750W HS (Y) | Yes | 7x Perf | Slide |
7Y99A00HEA | 7702P 64C 200W 2.0G | 1x 32GB 3200 | Onboard AHCI | 10x 2.5" (6xSAS + 4xAny) Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Perf | Slide |
7Y99A00MEA | 7742 64C 225W 2.25G | 1x 32GB 3200 | Onboard AHCI | 10x 2.5" (6xSAS + 4xAny) Open bay | Open | Open / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for Hong Kong, Taiwan, Korea (HTK)
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
TopSeller models with a 3-year model (machine type 7Y99) | ||||||||||
7Y991002CN | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A00ZCN | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A010CN | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A033CN | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y991003CN | 7502P 32C 180W 2.5G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A012CN | 7502P 32C 180W 2.5G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y991004CN | 7702P 64C 200W 2.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A013CN | 7702P 64C 200W 2.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for India
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
TopSeller models with a 3-year model (machine type 7Y99) | ||||||||||
7Y99A011SG | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Std | Fric |
7Y99A00SSG | 7402P 24C 180W 2.8G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A00PSG | 7502P 32C 180W 2.5G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
7Y99A00TSG | 7702P 64C 200W 2.0G | 1x 32GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 2x 750W HS (Y) | Yes | 6x Perf | Fric |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for Japan
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
TopSeller models with a 3-year model (machine type 7Y99) | ||||||||||
7Y99A01BJP | 7262 8C 155W 3.2G | 1x 16GB 3200 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 1x 750W HS (N) | Yes | 6x Std | Slide |
7Y99A015JP | 7302P 16C 155W 3.0G | 1x 16GB 3200 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 1x 750W HS (N) | Yes | 6x Std | Slide |
7Y99A019JP | 7502P 32C 180W 2.5G | 1x 16GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 1x 750W HS (N) | Yes | 6x Perf | Slide |
7Y99A01DJP | 7702P 64C 200W 2.0G | 1x 16GB 3200 | 730-8i 2GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 1x FH x16 / 0 | 1x 750W HS (N) | Yes | 6x Perf | Slide |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for Latin American countries (except Brazil)
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
Standard models with a 3-year model (machine type 7Y99) | ||||||||||
Models with third-generation AMD EPYC processors | ||||||||||
7Y99A01PLA | 7313P 16C 155W 3.0G | 1x 32GB 3200 | 730-8i 1GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A034LA | 7313P 16C 155W 3.0G | 1x 16GB 3200 | 540-8i | 8x 2.5" SAS Open bay | Open | Open / 1 | 1x 750W HS (Y) | Yes | 7x Std | Slide CMA |
Models with second-generation AMD EPYC processors | ||||||||||
7Y99A02ULA | 7232P 8C 120W 3.1G | 1x 16GB 2933 | 530-8i | 4x 3.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 550W (Y) | Yes | 6x Std | Slide |
7Y991000LA | 7262 8C 155W 3.2G | 1x 16GB 3200 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01MLA | 7262 8C 155W 3.2G | 1x 16GB 2933 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A02TLA | 7272 12C 120W 2.6G | 1x 16GB 2933 | 530-8i | 4x 3.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 550W (Y) | Yes | 6x Std | Slide |
7Y991001LA | 7302P 16C 155W 3.0G | 1x 32GB 3200 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01NLA | 7302P 16C 155W 3.0G | 1x 16GB 2933 | 530-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01QLA | 7402P 24C 180W 2.8G | 1x 32GB 2933 | 730-8i 1GB | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
7Y99A01RLA | 7502P 32C 180W 2.5G | 1x 32GB 2933 | 930-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
7Y99A01SLA | 7702P 64C 200W 2.0G | 1x 64GB 2933 | 930-8i | 8x 2.5" SAS Open bay | 4x1Gb 5719 | 3x LP x16 / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Models for USA and Canada
Model | AMD EPYC processor† | Memory | RAID | Drive bays | OCP | Slots* | Power supplies (cords) |
Front VGA |
Fans | Rail kit |
---|---|---|---|---|---|---|---|---|---|---|
Standard models with a 3-year model (machine type 7Y99) | ||||||||||
Models with 3rd-generation AMD EPYC processors | ||||||||||
7Y99A039NA | 7203P 8C 120W 2.8G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | 1x FH x16 / 0 | 2x 1100W (Y) | Yes | 6x Std | Slide |
7Y991005NA | 7203P 8C 120W 2.8G | 2x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 1100W (Y) | Yes | 6x Std | Slide |
7Y99A038NA | 7303P 16C 130W 2.4G | 1x 32GB 3200 | 930-8i | 8x 2.5" SAS Open bay | Open | 1x FH x16 / 0 | 2x 1100W (Y) | Yes | 6x Std | Slide |
7Y991006NA | 7303P 16C 130W 2.4G | 2x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 1100W (Y) | Yes | 6x Std | Slide |
Models with 2nd-generation AMD EPYC processors | ||||||||||
7Y99A028NA | 7282 16C 120W 2.4G | 1x 16GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A01ANA | 7302P 16C 155W 3.0G | 1x 16GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A02WNA | 7302P 16C 155W 3.0G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 750W HS (Y) | Yes | 6x Std | Slide |
7Y99A016NA | 7402P 24C 180W 2.8G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
7Y99A02VNA | 7402P 24C 180W 2.8G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 1100W (Y) | Yes | 6x Perf | Slide |
7Y99A017NA | 7502P 32C 180W 2.5G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
7Y99A018NA | 7702P 64C 200W 2.0G | 1x 32GB 3200 | Option | Optional 2.5" Open bay | Open | Open / 0 | 1x 1100W HS (Y) | Yes | 6x Perf | Slide |
† Processor description: AMD EPYC model, number of cores, thermal design power (TDP), core frequency
* Slots are listed as (x / y) where x = rear-accessible slots, y = internal slot)
Processors
The SR635 supports processors in the AMD EPYC family of processors. The server supports one processor.
Processor options
The table below lists the supported AMD processors.
All supported processors have the following characteristics:
- Third and second-generation AMD EPYC processors (formerly codenamed "Milan" and "Rome" respectively)
- 7 nm process technology
- Eight DDR4 memory channels
- 128 PCIe 4.0 I/O lanes
Part numbers: Processors do not include an option part number because there are no field upgrades supported.
Feature code | Description |
---|---|
Third-generation AMD EPYC processors | |
BY56 | ThinkSystem AMD EPYC 7203 8C 120W 2.8GHz Processor |
BY57 | ThinkSystem AMD EPYC 7203P 8C 120W 2.8GHz Processor |
BF7H | ThinkSystem AMD EPYC 72F3 8C 180W 3.7GHz Processor |
BY58 | ThinkSystem AMD EPYC 7303 16C 130W 2.4GHz Processor |
BY59 | ThinkSystem AMD EPYC 7303P 16C 130W 2.4GHz Processor |
BF76 | ThinkSystem AMD EPYC 7313 16C 155W 3.0GHz Processor |
BF7B | ThinkSystem AMD EPYC 7313P 16C 155W 3.0GHz Processor |
BF7E | ThinkSystem AMD EPYC 7343 16C 190W 3.2GHz Processor |
BF7D | ThinkSystem AMD EPYC 73F3 16C 240W 3.5GHz Processor |
BF78 | ThinkSystem AMD EPYC 7413 24C 180W 2.65GHz Processor |
BF72 | ThinkSystem AMD EPYC 7443 24C 200W 2.85GHz Processor |
BF79 | ThinkSystem AMD EPYC 7443P 24C 200W 2.85GHz Processor |
BF74 | ThinkSystem AMD EPYC 7453 28C 225W 2.75GHz Processor |
BF7G | ThinkSystem AMD EPYC 74F3 24C 240W 3.2GHz Processor |
BF7A | ThinkSystem AMD EPYC 7513 32C 200W 2.6GHz Processor |
BF77 | ThinkSystem AMD EPYC 7543 32C 225W 2.8GHz Processor |
BF71 | ThinkSystem AMD EPYC 7543P 32C 225W 2.8GHz Processor |
BF7F | ThinkSystem AMD EPYC 75F3 32C 280W 2.95GHz Processor |
BGQ5 | ThinkSystem AMD EPYC 7643 48C 225W 2.3GHz Processor |
BY5A | ThinkSystem AMD EPYC 7643P 48C 225W 2.3GHz Processor |
BF75 | ThinkSystem AMD EPYC 7663 56C 240W 2.0GHz Processor |
BY5B | ThinkSystem AMD EPYC 7663P 56C 240W 2.0GHz Processor |
BF7C | ThinkSystem AMD EPYC 7713 64C 225W 2.0GHz Processor |
BF70 | ThinkSystem AMD EPYC 7713P 64C 225W 2.0GHz Processor |
BF73 | ThinkSystem AMD EPYC 7763 64C 280W 2.45GHz Processor |
Second-generation AMD EPYC processors | |
B766 | ThinkSystem AMD EPYC 7232P 8C 120W 3.1GHz Processor |
B6VU | ThinkSystem AMD EPYC 7252 8C 120W 3.1GHz Processor |
B6TS | ThinkSystem AMD EPYC 7262 8C 155W 3.2GHz Processor |
BCE9 | ThinkSystem AMD EPYC 7F32 8C 180W 3.7GHz Processor |
B767 | ThinkSystem AMD EPYC 7272 12C 120W 2.9GHz Processor |
B6VZ | ThinkSystem AMD EPYC 7282 16C 120W 2.8GHz Processor |
B6TV | ThinkSystem AMD EPYC 7302 16C 155W 3.0GHz Processor |
B6VV | ThinkSystem AMD EPYC 7302P 16C 155W 3.0GHz Processor |
BCE8 | ThinkSystem AMD EPYC 7F52 16C 240W 3.5GHz Processor |
B6W0 | ThinkSystem AMD EPYC 7352 24C 155W 2.3GHz Processor |
B6VW | ThinkSystem AMD EPYC 7402 24C 180W 2.8GHz Processor |
B6TT | ThinkSystem AMD EPYC 7402P 24C 180W 2.8GHz Processor |
BCEA | ThinkSystem AMD EPYC 7F72 24C 240W 3.2GHz Processor |
B6TU | ThinkSystem AMD EPYC 7452 32C 155W 2.35 GHz Processor |
B5XG | ThinkSystem AMD EPYC 7502 32C 180W 2.5GHz Processor |
B6VX | ThinkSystem AMD EPYC 7502P 32C 180W 2.5GHz Processor |
BABP | ThinkSystem AMD EPYC 7532 32C 200W 2.4GHz Processor |
B6W2 | ThinkSystem AMD EPYC 7542 32C 225W 2.9GHz Processor |
B6W1 | ThinkSystem AMD EPYC 7552 48C 200W 2.2GHz Processor |
B6W3 | ThinkSystem AMD EPYC 7642 48C 225W 2.3GHz Processor |
BABN | ThinkSystem AMD EPYC 7662 64C 225W 2.0GHz Processor |
B6TR | ThinkSystem AMD EPYC 7702 64C 200W 2.0GHz Processor |
B6VY | ThinkSystem AMD EPYC 7702P 64C 200W 2.0GHz Processor |
B5XF | ThinkSystem AMD EPYC 7742 64C 225W 2.25 GHz Processor |
BAVP | ThinkSystem AMD EPYC 7H12 64C 280W 2.6GHz Processor |
Processor features
The following table lists the features of the supported processors.
P suffix: Processor models with a P suffix are designated as single-socket processors. They have identical features to the non-P equivalent processors.
The following table lists the features of the supported processors.
EPYC model** |
Cores / Threads |
Base Frequency |
Max Boost Frequency† |
L3 Cache | Memory channels |
Memory bus |
TDP |
---|---|---|---|---|---|---|---|
Third-generation AMD EPYC processors | |||||||
7203 / 7203P | 8 / 16 | 2.8GHz | 3.4 GHz | 64 MB | 8 | 3200 MHz | 120W |
72F3 | 8 / 16 | 3.7 GHz | 4.1 GHz | 256 MB | 8 | 3200 MHz | 180 W |
7303 / 7303P | 16 / 32 | 2.4GHz | 3.4 GHz | 64 MB | 8 | 3200 MHz | 130W |
7313 / 7313P | 16 / 32 | 3.0 GHz | 3.7 GHz | 128 MB | 8 | 3200 MHz | 155 W |
7343 | 16 / 32 | 3.2 GHz | 3.9 GHz | 128 MB | 8 | 3200 MHz | 190 W |
73F3 | 16/ 32 | 3.5 GHz | 4.0 GHz | 256 MB | 8 | 3200 MHz | 240 W |
7413 | 24 / 48 | 2.65 GHz | 3.6 GHz | 128 MB | 8 | 3200 MHz | 180 W |
7443 / 7443P | 24 / 48 | 2.85 GHz | 4.0 GHz | 128 MB | 8 | 3200 MHz | 200 W |
7453 | 28 / 56 | 2.75 GHz | 3.45 GHz | 64 MB | 8 | 3200 MHz | 225 W |
74F3 | 24 / 48 | 3.2 GHz | 4.0 GHz | 256 MB | 8 | 3200 MHz | 240 W |
7513 | 32 / 64 | 2.6 GHz | 3.65 GHz | 128 MB | 8 | 3200 MHz | 200 W |
7543 / 7543P | 32 / 64 | 2.8 GHz | 3.7 GHz | 256 MB | 8 | 3200 MHz | 225 W |
75F3 | 32 / 64 | 2.95 GHz | 4.0 GHz | 256 MB | 8 | 3200 MHz | 280 W |
7643 / 7643P | 48 / 96 | 2.3 GHz | 3.6 GHz | 256 MB | 8 | 3200 MHz | 225 W |
7663 / 7663P | 56 / 112 | 2.0 GHz | 3.5 GHz | 256 MB | 8 | 3200 MHz | 225 W |
7713 / 7713P | 64 / 128 | 2.0 GHz | 3.675 GHz | 256 MB | 8 | 3200 MHz | 225 W |
7763 | 64 / 128 | 2.45 GHz | 3.5 GHz | 256 MB | 8 | 3200 MHz | 280 W |
Second-generation AMD EPYC processors | |||||||
7232P | 8 / 16 | 3.1 GHz | 3.2 GHz | 32 MB | 8 | 3200 MHz* | 120 W |
7252 | 8 / 16 | 3.1 GHz | 3.2 GHz | 64 MB | 8 | 3200 MHz* | 120 W |
7262 | 8 / 16 | 3.2 GHz | 3.4 GHz | 128 MB | 8 | 3200 MHz | 155W |
7F32 | 8 / 16 | 3.7 GHz | 3.9 GHz | 128 MB | 8 | 3200 MHz | 180W |
7272 | 12 / 24 | 2.9 GHz | 3.2 GHz | 64 MB | 8 | 3200 MHz* | 120 W |
7282 | 16 / 32 | 2.8 GHz | 3.2 GHz | 64 MB | 8 | 3200 MHz* | 120 W |
7302 / 7302P | 16 / 32 | 3.0 GHz | 3.3 GHz | 128 MB | 8 | 3200 MHz | 155 W |
7F52 | 16 / 32 | 3.5 GHz | 3.9 GHz | 256 MB | 8 | 3200 MHz | 240W |
7352 | 24 / 48 | 2.3 GHz | 3.2 GHz | 128 MB | 8 | 3200 MHz | 155 W |
7402 / 7402P | 24 / 48 | 2.8 GHz | 3.35 GHz | 128 MB | 8 | 3200 MHz | 180 W |
7F72 | 24 / 48 | 3.2 GHz | 3.7 GHz | 192 MB | 8 | 3200 MHz | 240W |
7452 | 32 / 64 | 2.35 GHz | 3.35 GHz | 128 MB | 8 | 3200 MHz | 155 W |
7502 / 7502P | 32 / 64 | 2.5 GHz | 3.35 GHz | 128 MB | 8 | 3200 MHz | 180 W |
7532 | 32 / 64 | 2.4 GHz | 3.3 GHz | 256 MB | 8 | 3200 MHz | 200W |
7542 | 32 / 64 | 2.9 GHz | 3.4 GHz | 128 MB | 8 | 3200 MHz | 225 W |
7552 | 48 / 96 | 2.2 GHz | 3.3 GHz | 192 MB | 8 | 3200 MHz | 200 W |
7642 | 48 / 96 | 2.3 GHz | 3.3 GHz | 256 MB | 8 | 3200 MHz | 225 W |
7662 | 64 / 128 | 2.0 GHz | 3.3 GHz | 256 MB | 8 | 3200 MHz | 225W |
7702 / 7702P | 64 / 128 | 2.0 GHz | 3.35 GHz | 256 MB | 8 | 3200 MHz | 200 W |
7742 | 64 / 128 | 2.25 GHz | 3.4 GHz | 256 MB | 8 | 3200 MHz | 225 W |
7H12 | 64 / 128 | 2.6 GHz | 3.3 GHz | 256 MB | 8 | 3200 MHz | 280W |
† The maximum single-core frequency at with the processor is capable of operating
* This processor supports 8 memory channels at 3200 MHz, however performance is optimized for 4 channels at 2666 MHz
** Processors with a P suffix are single-socket capable processors
UEFI operating modes
The SR635 offers preset operating modes that affect energy consumption and performance. These modes are a collection of predefined low-level UEFI settings that simplify the task of tuning the server to suit your business and workload requirements.
The following table lists the feature codes that allow you to specify the mode you wish to preset in the factory for CTO orders.
UK and EU customers: For compliance with the ERP Lot9 regulation, you should select feature BFYA. For some systems, you may not be able to make a selection, in which case, it will be automatically derived by the configurator.
Feature code | Description |
---|---|
BFYA | Operating mode selection for: "Maximum Efficiency Mode" |
BFYB | Operating mode selection for: "Maximum Performance Mode" |
The preset modes for the SR635 are as follows:
- Maximum Efficiency Mode (feature BFYA): Maximizes performance/watt efficiency while maintaining reasonable performance
- Maximum Performance Mode (feature BFYB): Achieves maximum performance but with higher power consumption and lower energy efficiency.
For details about these preset modes, and all other performance and power efficiency UEFI settings offered in the SR635, see the paper "Tuning UEFI Settings for Performance and Energy Efficiency on AMD Processor-Based ThinkSystem Servers", available from https://lenovopress.lenovo.com/lp1267.
Memory options
The SR635 uses Lenovo TruDDR4 memory operating at up to 3200 MHz. The processors have 8 memory channels and support 2 DIMMs per channel, for a total of 16 DIMMs. The server supports up to 2TB of memory using 16x 128 GB 3DS RDIMMs.
The server supports these memory DIMMs:
- 2933 MHz DIMMs, that operate at 2933 MHz both at 1 DIMM per channel and 2 DIMMs per channel
- 3200 MHz DIMMs, that operate at 3200 MHz at 1 DIMM per channel, and at 2933 MHz at 2 DIMMs per channel
The following table lists the memory options that are available for the server.
Lenovo TruDDR4 memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. From a service and support standpoint, Lenovo TruDDR4 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
2933 MHz memory | |||
4ZC7A08739 | B7MS | ThinkSystem 8GB TruDDR4 2933MHz (1Rx8 1.2V) RDIMM-A | 16 |
4ZC7A08740 | B7MT | ThinkSystem 16GB TruDDR4 2933MHz (1Rx4 1.2V) RDIMM-A | 16 |
4ZC7A08741 | B7MU | ThinkSystem 16GB TruDDR4 2933MHz (2Rx8 1.2V) RDIMM-A | 16 |
4ZC7A08742 | B7MV | ThinkSystem 32GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM-A | 16 |
4ZC7A08744 | B7MW | ThinkSystem 64GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM-A | 16 |
4ZC7A15113 | B587 | ThinkSystem 128GB TruDDR4 2933MHz (4Rx4 1.2V) 3DS RDIMM | 16* |
3200 MHz memory | |||
4ZC7A15121 | B5XD | ThinkSystem 16GB TruDDR4 3200MHz (2Rx8 1.2V) RDIMM-A | 16 |
4ZC7A15122 | B5XE | ThinkSystem 32GB TruDDR4 3200MHz (2Rx4 1.2V) RDIMM-A | 16 |
4ZC7A15123 | B8NU | ThinkSystem 32GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM-A | 16 |
4ZC7A15124 | B5XC | ThinkSystem 64GB TruDDR4 3200MHz (2Rx4 1.2V) RDIMM-A | 16 |
4ZC7A15125 | B8NT | ThinkSystem 128GB TruDDR4 3200MHz (4Rx4, 1.2V) 3DS RDIMM-A | 16 |
* Supported in the SR635 only with an EPYC 7002 processor. Not supported with an EPYC 7003 processor.
The following rules apply when selecting the memory configuration:
- The 128GB 2933 MHz 3DS RDIMM, 4ZC7A15113, is only supported in the SR635 with an EPYC 7002 processor.
- The server supports RDIMMs and 3DS RDIMMs
- Mixing of RDIMMs and 3DS RDIMMs is not supported
- Mixing x4 and x8 DIMMs is supported, but not in the same channel
- Mixing of DIMM rank counts is supported. Follow the required installation order installing the DIMMs with the higher rank counts first.
- Mixing of DIMM capacities is supported, however only two different capacities are supported across all channels of the processor (eg 32GB and 64GB). Follow the required installation order installing the larger DIMMs first.
- Mixing of 3200 MHz and 2933 MHz DIMMs is supported. Installed memory will operate at the lower speed.
- Memory mirroring and memory rank sparing are not supported.
- When a GPU is added as a field upgrade, all empty DIMM slots must have a dummy DIMM blank installed in each DIMM slot, to ensure the optimal air flow. Ordering information is in the following table. For CTO orders, the dummy DIMMs are derived by the configurator.
Part number | Description | Quantity required |
---|---|---|
4M27A11810 | ThinkSystem Dummy DIMM Package Kit (contains 24 dummy memory DIMMs) |
1 |
For best performance, consider the following:
- Ensure the memory installed is at least the same speed as the memory bus of the selected processor.
- Populate memory DIMMs in quantities of 8 or 16, so that all memory channels are used.
- Populate memory channels so they all have the same total memory capacity.
- For more details on how to best configure the memory subsystem for performance, refer to the Lenovo Press paper “Balanced Memory Configurations with 2nd Gen and 3rd Gen AMD EPYC Processors” available from
https://lenovopress.com/lp1268-balanced-memory-configurations-with-amd-epyc-processors
The following memory protection technologies are supported:
- ECC detection/correction
- SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
- Patrol/Demand Scrubbing
- DRAM Address Command Parity with Replay
- DRAM Uncorrected ECC Error Retry
- Post Package Repair
Internal storage
The SR635 supports 4x 3.5-inch or 16x 2.5-inch drive bays or a combination of drive bays, depending on the selected chassis and backplane configuration. The server also supports configurations without any drive bays if desired.
All drives are hot-swap and are accessible from the front, from the rear, or from drive bays that are located in the middle of the server (accessible when you remove the top cover of the server).
The three drive bay zones are as follows:
- Front: 4x 3.5-inch hot-swap bays or up to 10x 2.5-inch hot-swap bays
- Mid (internal): 4x 2.5-inch hot-swap bays
- Rear: up to 2x 2.5-inch hot-swap bays
The server also supports one or two M.2 drives, installed in an M.2 adapter.
In this section:
NVMe drive support
PM983 hot-swap support: To support hot-swap of PM983 NVMe drives, the server needs to have UEFI v2.0 (Build ID CFE108O) or later installed.
The SR635 supports NVMe drives to maximize storage performance. The server supports up to 16 NVMe drives without oversubscription (that is, each x4 drive has a full x4 connection (4 lanes) to the processor):
- 10x NVMe drives in the front bays
- 4x NVMe drives in the mid bays
- 2x NVMe drives in the rear bays
The specifics of these configurations plus other NVMe-rich configurations are covered in the Supported drive bay combinations and Adapters selections sections.
The 10x NVMe drives at the front makes use of the 10-bay AnyBay backplane (feature B5VS) which requires SAS/SATA cabling and controllers as well as the NVMe cabling. However, if 16x NVMe drive bays are configured (ie all drive bays in the server populated with NVMe drives), then the server can be configured in the DCSC configurator without SAS/SATA cabling and controllers. Note that all 16x NVMe drive bays must be configured (using backplanes B5VS, B5VN and B5VQ); configurations of 10 or 12 or 14x NVMe drive bays will require SAS/SATA cabling and controllers.
15mm NVMe drives: 15mm NVMe SSDs are not supported in the mid or rear drive bays due to thermal requirements. Only 7mm NVMe drives are supported in those zones.
Front drive bays
The front drive bay zone supports the following configurations:
- 3.5-inch drive bays
- No backplane and no drives (supports field upgrades)
- 4x 3.5-inch SAS/SATA
- 2.5-inch drive bays
- No backplane and no drives (supports field upgrades)
- 8x 2.5-inch hot-swap SAS/SATA
- 6x 2.5-inch hot-swap SAS/SATA + 4x 2.5-inch hot-swap AnyBay
- 10x 2.5-inch hot-swap AnyBay
These configurations are shown in the following figure.
Figure 6. SR635 front drive bay configurations
The backplanes used to provide these drive bays are listed in the following table.
10x NVMe drive support: The server supports 10x 2.5-inch NVMe-only drive bays in the front of the server. Such support makes use of the 10-bay AnyBay backplane (feature B5VS), however the SAS/SATA connectors on the backplane are not connected, and no SAS/SATA cabling or controllers are configured.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
Front 3.5-inch drive backplanes | |||
See note* | AUW8 | ThinkSystem 1U 3.5" SATA/SAS 4-Bay Backplane (4x 3.5-inch SAS/SATA backplane) |
1 |
Front 2.5-inch drive backplanes | |||
See note* | B7K3 | ThinkSystem SR635 2.5" SATA/SAS 8-Bay Backplane (8x 2.5-inch SAS/SATA backplane) |
1 |
See note* | AUW9 | ThinkSystem 1U 10x2.5" (6x SAS/SATA 4x AnyBay) Backplane (10-bay 2.5-inch backplane with 6x SAS/SATA + 4x AnyBay bays†) |
1 |
See note* | B5VS | ThinkSystem 1U 10x2.5" PCIe Gen4 AnyBay Backplane (10-bay 2.5-inch backplane with 10x AnyBay bays†) |
1 |
* Backplanes are available as part numbers for field upgrades using upgrade kits, as described in the Field upgrades section below.
† AnyBay bays support SAS or SATA or NVMe drives; can also be configured as 10x NVMe drives without SAS/SATA cabling.
Mid drive bays
The SR635 optionally supports 4x 2.5-inch hot-swap NVMe drive bays installed in the middle of the server chassis. The drive bays are accessible by removing the top lid of the server and levering the mid drive chassis into an angled open position.
The drive bays, angled up, are shown in the following figure.
The backplanes used to provide these drive bays are listed in the following table.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
Mid - 2.5-inch drive backplanes | |||
See note* | B5VN | ThinkSystem 2.5” NVMe 4-Bay Middle Backplane (4x 2.5-inch NVMe backplane) |
1 |
* Backplanes are available as part numbers for field upgrades using upgrade kits, as described in the Field upgrades section below.
The use of drive bays in the mid-chassis area has the following configuration rules:
- Only NVMe drives are supported in the mid chassis area. SAS and SATA drives are not supported.
- The mid drive cage is only supported in conjunction with the 10x 2.5-inch AnyBay backplane (feature AUW9) or the 4x 3.5-inch SAS/SATA backplane (feature AUW8) for the front drives. The use of other front-drive backplanes with the mid cage is not supported.
- The mid drive cage occupies the same physical space as the M.2 module, internal PCIe slot (slot 4) and two of the three holders for RAID power module (supercaps). As a result, the M.2 module, slot 4 and two supercaps cannot be installed.
Rear drive bays
The SR635 supports hot-swap drives installed at the rear of the server chassis. Supported configurations are as follows:
- 2x 2.5-inch hot-swap SAS/SATA drive bays
- 2x 2.5-inch hot-swap NVMe drive bays
The configurations are shown in the following figure.
The backplanes used to provide these drive bays are listed in the following table.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
Rear - 2.5-inch drive backplanes | |||
See note* | B5VR | ThinkSystem SR635 2.5" SATA/SAS 2-Bay Rear Backplane (2x 2.5-inch SAS/SATA backplane) |
1 |
See note* | B5VQ | ThinkSystem 1U 2x2.5" NVMe Rear Backplane (2x 2.5-inch NVMe backplane) |
1 |
* Backplanes are available as part numbers for field upgrades using upgrade kits, as described in the Field upgrades section below.
The use of rear drive bays has the following configuration rules:
- Slots 2 and 3 are not available
- Slot 1 is a low-profile slot
- GPUs are not supported
Supported drive bay combinations
This section describes the various combinations of 3.5-inch and 2.5-inch drives that the server supports. The drive bay combinations are grouped based on the drive type at the front of the server, 3.5-inch or 2.5-inch.
3.5-inch drive bay chassis
The following table shows the supported combinations when the server is configured with a 3.5-inch chassis (where the front drive bays are 3.5-inch). The choice of storage controller for each configuration is listed in the Adapter selections section.
Config | Total drives |
Front bays (3.5") | Mid bays (2.5") | Rear bays (2.5") | |
---|---|---|---|---|---|
SAS/SATA | NVMe | SAS/SATA | NVMe | ||
A | 4 | 4 | 0 | 0 | 0 |
B | 6 | 4 | 0 | 2 | 0 |
C | 6 | 4 | 0 | 0 | 2 |
D | 8 | 4 | 4 | 0 | 0 |
2.5-inch drive bay chassis
The following table shows the supported combinations when the server is configured with a 2.5-inch chassis (where the front drive bays are 2.5-inch). The choice of storage controller for each configuration is listed in the Adapter selections section.
Config | Total drives |
Front bays (2.5") | Mid bays (2.5") | Rear bays (2.5") | |||
---|---|---|---|---|---|---|---|
SAS/SATA | AnyBay | NVMe | NVMe | SAS/SATA | NVMe | ||
2.5-inch chassis - only SAS/SATA drives in the front bays | |||||||
A | 8 | 8 | 0 | 0 | 0 | 0 | 0 |
B | 10 | 8 | 0 | 0 | 0 | 2 | 0 |
C | 10 | 8 | 0 | 0 | 0 | 0 | 2 |
2.5-inch chassis - mix of SAS/SATA-only bays and AnyBay bays in the front | |||||||
D | 10 | 6 | 4 | 0 | 0 | 0 | 0 |
E | 12 | 6 | 4 | 0 | 0 | 2 | 0 |
F | 12 | 6 | 4 | 0 | 0 | 0 | 2 |
2.5-inch chassis - all AnyBay bays in the front | |||||||
G | 10 | 0 | 10 | 0 | 0 | 0 | 0 |
H | 12 | 0 | 10 | 0 | 0 | 2 | 0 |
I | 12 | 0 | 10 | 0 | 0 | 0 | 2 |
J | 14 | 0 | 10 | 0 | 4 | 0 | 0 |
K | 16 | 0 | 10 | 0 | 4 | 2 | 0 |
L | 16 | 0 | 10 | 0 | 4 | 0 | 2 |
M | 16 | 0 | 0 | 10 | 4 | 0 | 2 |
Adapter selections
The following tables lists the supported drive bay combinations plus the list of supported controller combinations supported by each of those drive bay combinations. Information about the controllers can be found in the Controllers for internal storage section.
Cfg | Total drives |
Front bays (3.5") |
Mid bays (2.5") |
Rear bays (2.5") | Supported controller combinations (choose one) (OB = Onboard) |
|
---|---|---|---|---|---|---|
SAS/SATA | NVMe | SAS/SATA | NVMe | |||
A | 4 | 4 | 0 | 0 | 0 |
|
B | 6 | 4 | 0 | 2 | 0 |
|
C | 6 | 4 | 0 | 0 | 2 |
|
D | 8 | 4 | 4 | 0 | 0 |
|
* The configurations with 4 mid drives do not support the M.2 Module because the mid drive bays and the M.2 Module occupy the same physical space.
Cfg | Total drives |
Front bays (2.5") | Mid bays (2.5") |
Rear bays (2.5") | Supported controller combinations (choose one) (OB = Onboard) |
|||
---|---|---|---|---|---|---|---|---|
SAS/ SATA | AnyBay | NVMe | NVMe | SAS/ SATA | NVMe | |||
2.5-inch chassis - only SAS/SATA drives in the front bays | ||||||||
A | 8 | 8 | 0 | 0 | 0 | 0 | 0 |
|
B | 10 | 8 | 0 | 0 | 0 | 2 | 0 |
|
C | 10 | 8 | 0 | 0 | 0 | 0 | 2 |
|
2.5-inch chassis - mix of SAS/SATA-only bays and AnyBay bays in the front | ||||||||
D | 10 | 6 | 4 | 0 | 0 | 0 | 0 |
|
E | 12 | 6 | 4 | 0 | 0 | 2 | 0 |
|
F | 12 | 6 | 4 | 0 | 0 | 0 | 2 |
|
2.5-inch chassis - all AnyBay bays in the front | ||||||||
G | 10 | 0 | 10 | 0 | 0 | 0 | 0 |
|
H | 12 | 0 | 10 | 0 | 0 | 2 | 0 |
|
I | 12 | 0 | 10 | 0 | 0 | 0 | 2 |
|
J | 14 | 0 | 10 | 0 | 4 | 0 | 0 |
|
K | 16 | 0 | 10 | 0 | 4 | 2 | 0 |
|
L | 16 | 0 | 10 | 0 | 4 | 0 | 2 |
|
M | 16 | 0 | 0 | 10 | 4 | 0 | 2 |
|
* These configurations, with 12 total SATA drives connected to the onboard SATA controller, or 4 mid drive bays, do not support the use of the M.2 Module. The M.2 Module and the onboard SATA bays use the same ports on the system board and the mid drive bays occupy the same space as the M.2 Module.
Field upgrades
This section describes the available upgrades to the storage subsystem.
- Backplane upgrades
- Cable kits for 440 HBAs and RAID 940 adapters
- Cable kit for Onboard SATA controller upgrades (X30 adapters only)
- RAID flash power module (supercap)
- 2.5-inch drive bay fillers
Backplane upgrades
The following table lists the option part numbers for the backplane kits that allow you to add additional drive bays as field upgrades. The table also lists what major components are included in each kit.
When adding drive bays, you will also need to add the appropriate storage controller(s). Consult the tables in the Adapter selections section to determine what controller sections are supported and what additional controllers you will need. Controllers are described in the Controllers for internal storage section.
Use with X40 adapters: These backplane kits in the table below include SAS/SATA cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you are adding or upgrading to RAID 940 adapters or 440 HBAs (collectively called X40 adapters), you will need to also order an X40 cable kit. See the Cable kits for 440 HBAs and RAID 940 adapters section for details.
Part number |
Description | Maximum supported |
---|---|---|
Front - 3.5-inch drive backplane (see Front drive bays) | ||
4XH7A09825 |
ThinkSystem SR635 3.5" SATA/SAS 4-Bay Backplane Kit
|
1 |
Front - 2.5-inch drive backplanes (see Front drive bays) | ||
4XH7A09826 |
ThinkSystem SR635 2.5" SATA/SAS 8-Bay Backplane Kit
|
1 |
4XH7A09827 |
ThinkSystem SR635 2.5" 4 Gen3 AnyBay 10-Bay BP Kit
|
1 |
4XH7A09828 |
ThinkSystem SR635 2.5" 10 Gen4 AnyBay BP Kit
|
1 |
Mid - 2.5-inch drive backplane (see Mid drive bays) | ||
4XH7A09856 |
ThinkSystem SR635 2.5" NVMe Gen4 4-Bay Middle Drive Kit
|
1 |
Rear - 2.5-inch drive backplanes (see Rear drive bays) | ||
4XH7A09852 |
ThinkSystem SR635 2.5" SATA/SAS 2-Bay Rear Drive Kit
|
1 |
4XH7A80466 |
ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit v2
|
1 |
4XH7A09853 |
ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit
|
1 |
† AnyBay bays support SAS or SATA or NVMe drives
Cable kits for 440 HBAs and RAID 940 adapters
The backplane kits listed in the preceding table include cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you wish to use the backplane kits with RAID 940 adapters or 440 HBAs (collectively called X40 adapters), then you will also need to order an additional X40 cable kit to use instead of the cables in the backplane kit.
Unused cables: When adding an X40 adapter, you will order both the backplane kit and the relevant X40 cable kit, however the SAS/SATA data cable(s) in the backplane kit will not be used.
Upgrades from onboard SATA: If you are upgrading a system that currently uses the onboard SATA controller and has all necessary backplanes, simply order the relevant X40 cable kit as listed in the table.
Backplane kits with X30 cables | X40 cable kits also needed | ||
---|---|---|---|
Front - 3.5-inch drive backplane (see Front drive bays) | |||
4XH7A09825 | ThinkSystem SR635 3.5" SATA/SAS 4-Bay Backplane Kit | 4XH7A61120 | ThinkSystem SR635 3.5" SAS/SATA 4-Bay X40 RAID Cable Kit |
Front - 2.5-inch drive backplanes (see Front drive bays) | |||
4XH7A09826 | ThinkSystem SR635 2.5" SATA/SAS 8-Bay Backplane Kit | 4XH7A61121 | ThinkSystem SR635 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit |
4XH7A09827 | ThinkSystem SR635 2.5" 4 Gen3 AnyBay 10-Bay BP Kit | 4XH7A61136 | ThinkSystem SR635 Front 6x2.5" SAS/SATA + 4x2.5" AnyBay X40 RAID Cable Kit |
4XH7A09828 | ThinkSystem SR635 2.5" 10 Gen4 AnyBay BP Kit | 4XH7A61127 | ThinkSystem SR635 2.5" SAS/SATA/AnyBay 10-Bay X40 RAID Cable Kit |
Mid - 2.5-inch drive backplane (see Mid drive bays) | |||
4XH7A09856 | ThinkSystem SR635 2.5" NVMe Gen4 4-Bay Middle Drive Kit | None | Not supported – NVMe only |
Rear - 2.5-inch drive backplanes (see Rear drive bays) | |||
4XH7A09852 | ThinkSystem SR635 2.5" SATA/SAS 2-Bay Rear Drive Kit | 4XH7A61128 | ThinkSystem SR635 2.5" SAS/SATA 2-Bay Rear Backplane X40 RAID Cable Kit |
4XH7A80466 | ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit v2 | None | Not supported – NVMe only |
4XH7A09853 | ThinkSystem SR635 2.5" NVMe Gen4 2-Bay Rear Drive Kit | None | Not supported – NVMe only |
Cable kit for Onboard SATA controller upgrades (X30 adapters only)
If your existing server is configured with drive backplanes that are connected to onboard SATA ports and you wish to upgrade to an X30 RAID adapter or SAS HBA (RAID 930, 730, 530 adapters and 430 HBAs), you will need to order the cable kit listed in the following table along with the adapter(s). The cable kit includes the additional cables you will need to connect the existing backplane to the new X30 adapter. Note that the kit includes the cables needed for all supported combinations of backplanes; this means that some of the cables in the kit will not be used.
For X40 RAID adapters and HBAs, instead order one of the X40 cable kits listed in the Cable kits for 440 HBAs and RAID 940 adapters section.
Part number | Feature code | Description |
---|---|---|
4X97A59749 | BCCC |
ThinkSystem SR635 SAS Cable Kit, contains five cables:
|
The cables in the kit are used with existing backplanes as listed in the following table.
Existing backplane | Needed cables |
---|---|
Front 3.5-inch 4x SATA/SATA Backplane | 800mm MiniSAS-HD to MiniSAS-HD Cable C, SC17A50746 |
Front 2.5-inch 8x SAS/SATA Backplane | Front BP SAS/SATA Combo Cable A, SC17A59349 |
Front 2.5-inch 4x AnyBay+6x SAS/SATA Backplane | 800mm MiniSAS-HD to MiniSAS-HD Cable C, SC17A50746 |
Front 2.5-inch 10x AnyBay Backplane | Front 1U 10 AnyBay BP SAS/SATA Combo Cable, SC17A59347 800mm Slimline4X to MiniSAS-HD Cable C, SC17A50732 |
Rear 2.5-inch 2x SAS/SATA Backplane | 250mm HBA HD to HD Cable D, SC17A50750 |
RAID flash power module (supercap)
If you plan to add one of the RAID adapters that includes a RAID flash power module (supercap) as a field upgrade, then you will also need to order a Supercap installation kit for the power module. For CTO orders, the components in the installation kit are automatically derived when you select the RAID adapter. The adapters that this applies to are as follows:
- ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter
- ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
- ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
- ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
- ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter
There are three possible locations for supercaps, as shown in the following figure.
Figure 9. Location of all three supercaps in the SR635
The following configuration rules apply to the use of supercaps:
- Locations 1 and 2 are not available if the mid-chassis drive cage is installed
- Location 3 is only available with 2.5-inch front drive bays. It is not available if 3.5-inch front drives are used
When adding a RAID adapter and supercap as a field upgrade, order the supercap installation kit list listed in the following table.
Part number | Feature code | Description |
---|---|---|
4XH7A09847 | B72A |
ThinkSystem SR635/SR655 Supercap Installation Kit
|
The following figure shows the use of the components of the option kit to install 1 or 2 supercaps. The third supercap is installed in location 3 in front of the cooling fans and behind the front operator panel as shown in the preceding figure (2.5-inch chassis only; not available with 3.5-inch front drives).
2.5-inch drive bay fillers
Backplane option kits include the necessary drive bay fillers, however if needed, additional blanks can be ordered as listed in the following table.
Part number | Description |
---|---|
4XH7A99569 | ThinkSystem 2.5" 1x1 HDD Filler by 8 units (contains 8x single drive-bay fillers) |
M.2 drives
The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution or as additional storage. The M.2 drives install into an M.2 module which is mounted horizontally in the server adjacent to the internal storage controller slot as shown in the Components and connectors section.
M.2 restriction: The M.2 Module cannot be used in certain drive bay combinations:
- When 12 SATA or AnyBay drive bays are configured (10 front, 2 rear) and the SATA drives are connected to the onboard SATA controller (onboard SATA and M.2 use the same connector)
- When 4 mid-chassis drive bays are configured (M.2 occupies the same space)
See Adapter selections for the specific combinations where the M.2 Module is not supported.
There are two M.2 modules supported, as listed in the following table. The table also includes the cable kit needed for field upgrades.
Field upgrades: When ordering either option part number as a field upgrade, you will also need to order the M.2 Cable Kit which includes the necessary cables to connect the M.2 modules to the server. For CTO orders, the cable kit is not required; the cable and brackets are automatically included in the order.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
4Y37A09739 | B5XH | ThinkSystem M.2 SATA 2-Bay RAID Enablement Kit | 1 |
4Y37A09738 | B5XJ | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit | 1 |
4X97A59730 | None |
ThinkSystem SR635/SR655 M.2 Cable Kit
|
1 |
Supported drives are listed in the Internal drive options section.
The SATA RAID Enablement Kit has the following features:
- Supports one or two SATA M.2 drives
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280)
- RAID support via an onboard Marvell 88SE9230 SATA RAID Controller
- Support JBOD, RAID-0 and RAID-1 (RAID support requires two M.2 drives)
- PCIe 2.0 x2 host interface; 6Gbps SATA connection to the drives
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
The SATA/NVMe Enablement Kit has the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- When two drives installed, they must be either both SATA or both NVMe
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280)
- JBOD support only; no RAID support
- Either 6Gbps SATA or PCIe 3.0 x1 interface to the drives depending on the drives installed
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
For further details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters
Controllers for internal storage
The SR635 offers a variety of controller options for internal drives:
- Onboard SATA ports for up to 12 SATA drives
- RAID adapters and HBAs for SAS/SATA drives
- Onboard NVMe ports (for up to 16 NVMe drives)
The following table lists the adapters used for the internal storage of the server.
Part number |
Feature code |
Description | Power module (supercap) |
Slots supported |
Maximum supported |
---|---|---|---|---|---|
SAS/SATA RAID - PCIe 3.0 | |||||
7Y37A01082 | AUNG | ThinkSystem RAID 530-8i PCIe 12Gb Adapter | No | 4, 1, 3, 2 | 2 |
4Y37A78834 | BMFT | ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter | No | 4, 1, 3, 2 | 2 |
7Y37A01083* | AUNH* | ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | No | 4, 1, 3, 2 | 2 |
4Y37A09722 | B4RQ | ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter | Included | 4, 1, 3, 2 | 1 |
7Y37A01084 | AUNJ | ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | Included | 4, 1, 3, 2 | 1 |
7Y37A01085 | AUNK | ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | Included | 4, 1, 3, 2 | 1 |
SAS/SATA RAID - PCIe 4.0 (No support for Tri-Mode) | |||||
4Y37A09728 | B8NY | ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter | Included | 4, 1, 3, 2 | 1 |
4Y37A78600 | BM35 | ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter | Included | 4, 1, 3, 2 | 1 |
SAS/SATA HBA - PCIe 3.0 | |||||
7Y37A01088 | AUNL | ThinkSystem 430-8i SAS/SATA 12Gb HBA | No | 1, 3, 2 | 2 |
7Y37A01089 | AUNM | ThinkSystem 430-16i SAS/SATA 12Gb HBA | No | 1, 3, 2 | 1 |
SAS/SATA HBA - PCIe 4.0 | |||||
4Y37A78601 | BM51 | ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA | No | 4, 1, 3, 2 | 2 |
4Y37A78602 | BM50 | ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA | No | 4, 1, 3, 2 | 1 |
* The RAID 730-8i 1GB Cache adapter is not available in USA and Canada.
For a comparison of the functions of the supported storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference#sr635-support=SR635
For more information about the adapters see the product guides in the RAID adapters or HBA sections of the Lenovo Press web site:
https://lenovopress.com/servers/options/raid
https://lenovopress.com/servers/options/hba
Configuration notes:
- Tri-Mode not supported: In the SR635, the Tri-Mode (Trimode) feature of the RAID 940-8i and 940-16i adapters (support for NVMe U.3 drives) is not supported.
- Field upgrades: If you are adding a RAID adapter to the SR635 as a field upgrade, you will need a Supercap Installation Kit as described in the Field upgrades section. For use of 940 RAID adapters or 440 HBAs, you will also need a cable kit. Take note of the configuration rules in that section.
- RAID 530-8i firmware: If you plan to use the RAID 530-8i in the SR655, it must have firmware 50.3.0-1032 or later applied before it can be used in the server. If the adapter you plan to use has older firmware (for example, you are using an adapter you previously purchased), it must first be upgrade by installing it in another server and upgrading the firmware there. For more information, see Support tip HT509177.
Internal drive options
The following tables list the drive options for internal storage of the server.
2.5-inch hot-swap drives:
3.5-inch hot-swap drives:
M.2 drives:
M.2 drive support: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.
SED support: The tables include a column to indicate which drives support SED encryption. The encryption functionality can be disabled if needed. Note: Not all SED-enabled drives have "SED" in the description.
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch hot-swap HDDs - 12 Gb SAS 15K | ||||
7XB7A00021 | AULV | ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00022 | AULW | ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00023 | AULX | ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD | No | 12 |
2.5-inch hot-swap HDDs - 12 Gb SAS 10K | ||||
7XB7A00024 | AULY | ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00025 | AULZ | ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00026 | AUM0 | ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00027 | AUM1 | ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00028 | AUM2 | ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD | No | 12 |
2.5-inch hot-swap HDDs - 12 Gb NL SAS | ||||
7XB7A00034 | AUM6 | ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD | No | 12 |
7XB7A00035 | AUM7 | ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD | No | 12 |
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K | ||||
7XB7A00031 | AUM5 | ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED | Support | 12 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch hot-swap HDDs - 6 Gb NL SATA | ||||
7XB7A00036 | AUUE | ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD | No | 12 |
7XB7A00037 | AUUJ | ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 12 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A80340 | BNW8 | ThinkSystem 2.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD | Support | 12 |
4XB7A80341 | BNW9 | ThinkSystem 2.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD | Support | 12 |
4XB7A80342 | BNW6 | ThinkSystem 2.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD | Support | 12 |
4XB7A80343 | BP3K | ThinkSystem 2.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD | Support | 12 |
2.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD) | ||||
4XB7A80318 | BNWC | ThinkSystem 2.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD | Support | 12 |
4XB7A80319 | BNWE | ThinkSystem 2.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD | Support | 12 |
4XB7A80320 | BNWF | ThinkSystem 2.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD | Support | 12 |
4XB7A80321 | BP3E | ThinkSystem 2.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD | Support | 12 |
4XB7A80322 | BP3J | ThinkSystem 2.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD | Support | 12 |
4XB7A80323 | BP3D | ThinkSystem 2.5" PM1653 30.72TB Read Intensive SAS 24Gb HS SSD | Support | 12 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD) | ||||
4XB7A83214 | BR10 | ThinkSystem 2.5" Nytro 3750 400GB Write Intensive SAS 12Gb HS SSD | Support | 12 |
4XB7A83215 | BR0Z | ThinkSystem 2.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD | Support | 12 |
4XB7A83216 | BR0Y | ThinkSystem 2.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD | Support | 12 |
4XB7A83217 | BR0X | ThinkSystem 2.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD | Support | 12 |
4XB7A70006 | BG07 | ThinkSystem 2.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A70005 | BG06 | ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A70007 | BFZZ | ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD SED | Support | 12 |
4XB7A70004 | BG05 | ThinkSystem 2.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A70003 | BG04 | ThinkSystem 2.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A10219 | B4Y4 | ThinkSystem 2.5" SS530 400GB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A10230 | B4Y5 | ThinkSystem 2.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A10231 | B4Y6 | ThinkSystem 2.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A10232 | B4Y7 | ThinkSystem 2.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD | No | 12 |
2.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A17062 | B8HU | ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A17063 | B8J4 | ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A17065 | B8JA | ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD | No | 12 |
2.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD) | ||||
4XB7A38175 | B91A | ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A38176 | B91B | ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A17054 | B91C | ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD | No | 12 |
4XB7A17055 | B91D | ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD | No | 12 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A90884 | BYM2 | ThinkSystem 2.5" VA 480GB Mixed Use SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90885 | BYM4 | ThinkSystem 2.5" VA 960GB Mixed Use SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90886 | BYM5 | ThinkSystem 2.5" VA 1.92TB Mixed Use SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90887 | BYM6 | ThinkSystem 2.5" VA 3.84TB Mixed Use SATA 6Gb HS SSD v2 | No | 12 |
4XB7A82289 | BQ21 | ThinkSystem 2.5" 5400 MAX 480GB Mixed Use SATA 6Gb HS SSD | Support | 12 |
4XB7A82290 | BQ24 | ThinkSystem 2.5" 5400 MAX 960GB Mixed Use SATA 6Gb HS SSD | Support | 12 |
4XB7A82291 | BQ22 | ThinkSystem 2.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD | Support | 12 |
4XB7A82292 | BQ23 | ThinkSystem 2.5" 5400 MAX 3.84TB Mixed Use SATA 6Gb HS SSD | Support | 12 |
4XB7A17125 | BA7Q | ThinkSystem 2.5" S4620 480GB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A17126 | BA4T | ThinkSystem 2.5" S4620 960GB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A17127 | BA4U | ThinkSystem 2.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A17128 | BK7L | ThinkSystem 2.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A17087 | B8J1 | ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17089 | B8J6 | ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17090 | B8JE | ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17091 | B8J7 | ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A64222 | BEMB | ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD SED | Support | 12 |
4XB7A13633 | B49L | ThinkSystem 2.5" S4610 240GB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A13634 | B49M | ThinkSystem 2.5" S4610 480GB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A13635 | B49N | ThinkSystem 2.5" S4610 960GB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A13636 | B49P | ThinkSystem 2.5" S4610 1.92TB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A13637 | B49Q | ThinkSystem 2.5" S4610 3.84TB Mixed Use SATA 6Gb HS SSD | No | 12 |
4XB7A10238 | B489 | ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A10239 | B48A | ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD | No | 12 |
2.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD) | ||||
4XB7A90872 | BYLQ | ThinkSystem 2.5" VA 240GB Read Intensive SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90873 | BYLR | ThinkSystem 2.5" VA 480GB Read Intensive SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90874 | BYLS | ThinkSystem 2.5" VA 960GB Read Intensive SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90875 | BYLT | ThinkSystem 2.5" VA 1.92TB Read Intensive SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90876 | BYLU | ThinkSystem 2.5" VA 3.84TB Read Intensive SATA 6Gb HS SSD v2 | No | 12 |
4XB7A90877 | BYLV | ThinkSystem 2.5" VA 7.68TB Read Intensive SATA 6Gb HS SSD v2 | No | 12 |
4XB7A89423 | BXDY | ThinkSystem 2.5" CM893a 1.92TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A87524 | BWKN | ThinkSystem 2.5" PM893a 480GB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A87525 | BWKM | ThinkSystem 2.5" PM893a 960GB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A87526 | BWKL | ThinkSystem 2.5" PM893a 1.92TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A87527 | BWKK | ThinkSystem 2.5" PM893a 3.84TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A87528 | BYLK | ThinkSystem 2.5" PM893a 7.68TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A82258 | BQ1Q | ThinkSystem 2.5" 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A82259 | BQ1P | ThinkSystem 2.5" 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A82260 | BQ1R | ThinkSystem 2.5" 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A82261 | BQ1X | ThinkSystem 2.5" 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A82262 | BQ1S | ThinkSystem 2.5" 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A82263 | BQ1T | ThinkSystem 2.5" 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD | Support | 12 |
4XB7A72438 | BM8B | ThinkSystem 2.5" PM893 480GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A72439 | BM8A | ThinkSystem 2.5" PM893 960GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A72440 | BM89 | ThinkSystem 2.5" PM893 1.92TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A72441 | BM88 | ThinkSystem 2.5" PM893 3.84TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A72442 | BM87 | ThinkSystem 2.5" PM893 7.68TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A17072 | B99D | ThinkSystem 2.5" S4520 240GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A17101 | BA7G | ThinkSystem 2.5" S4520 480GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A17102 | BA7H | ThinkSystem 2.5" S4520 960GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A17103 | BA7J | ThinkSystem 2.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A17104 | BK77 | ThinkSystem 2.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A17105 | BK78 | ThinkSystem 2.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A38271 | BCTC | ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A38272 | BCTD | ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A38273 | BCTE | ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A38274 | BCTF | ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A38275 | BCTG | ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17075 | B8HV | ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17076 | B8JM | ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17077 | B8HP | ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A38141 | BE29 | ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD SED | Support | 12 |
4XB7A17078 | B8J5 | ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17079 | B8JP | ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A17080 | B8J2 | ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A38185 | B9AC | ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD | No | 12 |
4XB7A38144 | B7EW | ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD | No | 12 |
4XB7A38145 | B7EX | ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD | No | 12 |
4XB7A38146 | B7EY | ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD | No | 12 |
4XB7A10247 | B498 | ThinkSystem 2.5" S4510 240GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A10248 | B499 | ThinkSystem 2.5" S4510 480GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A10249 | B49A | ThinkSystem 2.5" S4510 960GB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A13622 | B49B | ThinkSystem 2.5" S4510 1.92TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A13623 | B49C | ThinkSystem 2.5" S4510 3.84TB Read Intensive SATA 6Gb HS SSD | No | 12 |
4XB7A10153 | B2X2 | ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A10154 | B2X3 | ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A10155 | B2X4 | ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A10156 | B2X5 | ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
4XB7A10157 | B2X6 | ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD | No | 12 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7B01879 | C6M2 | ThinkSystem 2.5" U.2 Solidigm P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7B01880 | C6M3 | ThinkSystem 2.5" U.2 Solidigm P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7B01881 | C6M4 | ThinkSystem 2.5" U.2 Solidigm P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7B01882 | C6M5 | ThinkSystem 2.5" U.2 Solidigm P5620 12.8TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A91175 | BZEH | ThinkSystem 2.5 U.2 9400 MAX 25.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD (Non-SED) | No | 10* |
4XB7A17129 | BNEG | ThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A17130 | BNEH | ThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A17133 | BNEZ | ThinkSystem 2.5" U.2 P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A17136 | BA4V | ThinkSystem 2.5" U.2 P5620 12.8TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A17152 | BCFV | ThinkSystem 2.5" U.2 P5600 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | No | 10* |
4XB7A17153 | BCFR | ThinkSystem 2.5" U.2 P5600 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | No | 10* |
4XB7A17154 | BCFS | ThinkSystem 2.5" U.2 P5600 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | No | 10* |
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A79639 | BNF1 | ThinkSystem 2.5" U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13967 | BNEJ | ThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13970 | BNEY | ThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13971 | BNEL | ThinkSystem 2.5" U.3 7450 MAX 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A84056 | BRG0 | ThinkSystem 2.5" U.3 7450 MAX 12.8TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A64175 | BE03 | ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD | No | 10* |
4XB7A17112 | B96Z | ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD | No | 10* |
4XB7A17113 | B96T | ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD | No | 10* |
4XB7A17114 | B96P | ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD | No | 10* |
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD) | ||||
4XB7B01867 | C6MA | ThinkSystem 2.5" U.2 Solidigm P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7B01868 | C6MB | ThinkSystem 2.5" U.2 Solidigm P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7B01869 | C6MC | ThinkSystem 2.5" U.2 Solidigm P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7B01870 | C7NZ | ThinkSystem 2.5" U.2 Solidigm P5520 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A90099 | BXMB | ThinkSystem 2.5" U.2 PM9A3 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A90100 | BXMA | ThinkSystem 2.5" U.2 PM9A3 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A90101 | BXM9 | ThinkSystem 2.5" U.2 PM9A3 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13941 | BMGD | ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13942 | BMGE | ThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13943 | BNEF | ThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A13631 | BNEQ | ThinkSystem 2.5" U.2 P5520 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A17145 | BCFT | ThinkSystem 2.5" U.2 P5500 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | No | 10* |
4XB7A17146 | BCFW | ThinkSystem 2.5" U.2 P5500 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | No | 10* |
4XB7A17147 | BCFU | ThinkSystem 2.5" U.2 P5500 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | No | 10* |
4XB7A38196 | BC4Y | ThinkSystem U.2 PM1733 1.92TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | No | 10* |
4XB7A38197 | BC4Z | ThinkSystem U.2 PM1733 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | No | 10* |
4XB7A38283 | BE2E | ThinkSystem U.2 PM1733 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | No | 10* |
4XB7A38284 | BE2F | ThinkSystem U.2 PM1733 15.36TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | No | 10* |
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD) | ||||
4XB7A91176 | BZC1 | ThinkSystem 2.5" U.3 6500 ION 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A81951 | BPKX | ThinkSystem 2.5" U.3 PM1733a 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A81952 | BPKY | ThinkSystem 2.5" U.3 PM1733a 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A81953 | BPKZ | ThinkSystem 2.5" U.3 PM1733a 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A81954 | BPL0 | ThinkSystem 2.5" U.3 PM1733a 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A81999 | BPL1 | ThinkSystem 2.5" U.3 PM1733a 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A79646 | BNF3 | ThinkSystem 2.5" U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A79647 | BNF2 | ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A79648 | BNF5 | ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A79649 | BNF4 | ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
4XB7A83097 | BQAV | ThinkSystem 2.5" U.3 7450 PRO 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Support | 10* |
* All NVMe drives, with the exception of PM983 drives, are only supported in the front drive bays due to thermal requirements
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A13936 | B589 | ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | No | 10* |
4XB7A13937 | B58A | ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | No | 10* |
4XB7A13938 | B58B | ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | No | 10* |
4XB7A08516 | B21W | ThinkSystem U.2 Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | No | 10* |
4XB7A08517 | B21X | ThinkSystem U.2 Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | No | 10* |
4XB7A08518 | B21Y | ThinkSystem U.2 Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | No | 10* |
4XB7A08519 | B2XJ | ThinkSystem U.2 Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | No | 10* |
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD) | ||||
4XB7A10202 | B58F | ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | No | 10* |
4XB7A10204 | B58G | ThinkSystem 2.5" U.2 P4510 2.0TB Read Intensive NVMe PCIe 3.0 x4 HS SSD | No | 10* |
4XB7A10205 | B58H | ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | No | 10* |
4XB7A08513 | B58J | ThinkSystem U.2 Intel P4510 8.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | No | 10* |
4XB7A10175 | B34N | ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD | No | 16 |
4XB7A10176 | B34P | ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD | No | 16 |
4XB7A10177 | B4D3 | ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | No | 16 |
* All NVMe drives, with the exception of PM983 drives, are only supported in the front drive bays due to thermal requirements
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
3.5-inch hot-swap HDDs - 12 Gb SAS 10K | ||||
7XB7A00063 | B1JJ | ThinkSystem 3.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD | No | 4 |
3.5-inch hot-swap HDDs - 12 Gb SAS 15K | ||||
7XB7A00039 | AUU3 | ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD | No | 4 |
7XB7A00040 | AUUC | ThinkSystem 3.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD | No | 4 |
3.5-inch hot-swap HDDs - 12 Gb NL SAS | ||||
4XB7B01233 | C5WY | ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00042 | AUU5 | ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD | No | 4 |
4XB7B01235 | C5X9 | ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00043 | AUU6 | ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD | No | 4 |
4XB7B01237 | C5XB | ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00044 | AUU7 | ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7B01239 | C5XD | ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A17222 | BCM2 | ThinkSystem SR635 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7B01241 | C5XF | ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00046 | AUUG | ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7A93788 | C4DA | ThinkSystem 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A17223 | BCM6 | ThinkSystem SR635/SR655 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7A17224 | BCM4 | ThinkSystem SR635/SR655 3.5" 14TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7A13911 | B7EZ | ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7A93786 | C4D8 | ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A76340 | BHX6 | ThinkSystem SR635/SR645/SR655 3.5" 18TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7A80353 | BPKU | ThinkSystem 3.5" 20TB 7.2K SAS 12Gb Hot Swap 512e HDD | No | 4 |
4XB7A93784 | C4D6 | ThinkSystem 3.5" 20TB 7.2K SAS 12Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A83766 | BTR7 | ThinkSystem 3.5" 22TB 7.2K SAS 12Gb Hot Swap 512e HDD | Support | 4 |
3.5-inch hot-swap SED HDDs - 12 Gb NL SAS | ||||
7XB7A00047 | AUUH | ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD FIPS | Support | 4 |
7XB7A00048 | B0YP | ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS | Support | 4 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
3.5-inch hot-swap HDDs - 6 Gb NL SATA | ||||
4XB7A97045 | C5X6 | ThinkSystem 3.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD v2 | Support | 4 |
4XB7B01234 | C5X8 | ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00050 | AUUD | ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD | No | 4 |
4XB7B01236 | C5XA | ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00051 | AUU8 | ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD | No | 4 |
4XB7B01238 | C5XC | ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00052 | AUUA | ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7B01240 | C5XE | ThinkSystem 3.5" 8TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A17225 | BCM7 | ThinkSystem SR635 3.5" 8TB 7.2K SATA 12Gb Hot Swap 512e HDD | No | 4 |
4XB7B01242 | C5X7 | ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
7XB7A00054 | AUUB | ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7A93787 | C4D9 | ThinkSystem 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A17226 | BCM5 | ThinkSystem SR635/SR655 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7A38184 | BCM3 | ThinkSystem SR635/SR655 3.5" 14TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7A13914 | B7F0 | ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7A93785 | C4D7 | ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A76341 | BHX5 | ThinkSystem SR635/SR645/SR655 3.5" 18TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7A80354 | BPKV | ThinkSystem 3.5" 20TB 7.2K SATA 6Gb Hot Swap 512e HDD | No | 4 |
4XB7A93783 | C4D5 | ThinkSystem 3.5" 20TB 7.2K SATA 6Gb Hot Swap 512e HDD v2 | Support | 4 |
4XB7A83765 | BTR8 | ThinkSystem 3.5" 22TB 7.2K SATA 6Gb Hot Swap 512e HDD | Support | 4 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
3.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A80344 | BNW7 | ThinkSystem 3.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD | Support | 4 |
4XB7A80345 | BNWA | ThinkSystem 3.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD | Support | 4 |
4XB7A80346 | BNWB | ThinkSystem 3.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD | Support | 4 |
4XB7A80347 | BP3G | ThinkSystem 3.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD | Support | 4 |
3.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD) | ||||
4XB7A80324 | BNWD | ThinkSystem 3.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD | Support | 4 |
4XB7A80325 | BNWG | ThinkSystem 3.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD | Support | 4 |
4XB7A80326 | BNWH | ThinkSystem 3.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD | Support | 4 |
4XB7A80327 | BP3F | ThinkSystem 3.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD | Support | 4 |
4XB7A80328 | BP3H | ThinkSystem 3.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD | Support | 4 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
3.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD) | ||||
4XB7A83218 | BR0W | ThinkSystem 3.5" Nytro 3750 400GB Write Intensive SAS 12Gb HS SSD | Support | 4 |
4XB7A83219 | BR0V | ThinkSystem 3.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD | Support | 4 |
4XB7A83220 | BR0U | ThinkSystem 3.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD | Support | 4 |
4XB7A83221 | BR0T | ThinkSystem 3.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD | Support | 4 |
4XB7A70011 | BG03 | ThinkSystem 3.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A70010 | BG02 | ThinkSystem 3.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A70009 | BG01 | ThinkSystem 3.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A70008 | BG00 | ThinkSystem 3.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A10234 | B4Y8 | ThinkSystem 3.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A10235 | B4Y9 | ThinkSystem 3.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A10236 | B4YA | ThinkSystem 3.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD | No | 4 |
3.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A17066 | B8HT | ThinkSystem 3.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A17043 | B8JN | ThinkSystem 3.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A17067 | B8JK | ThinkSystem 3.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A17068 | B8JG | ThinkSystem 3.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD | No | 4 |
3.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD) | ||||
4XB7A17058 | B91E | ThinkSystem 3.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD | No | 4 |
4XB7A17059 | BEVK | ThinkSystem 3.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD | No | 4 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
3.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD) | ||||
4XB7A90888 | BYM3 | ThinkSystem 3.5" VA 480GB Mixed Use SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90889 | BYM7 | ThinkSystem 3.5" VA 960GB Mixed Use SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90890 | BYM8 | ThinkSystem 3.5" VA 1.92TB Mixed Use SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90891 | BYLX | ThinkSystem 3.5" VA 3.84TB Mixed Use SATA 6Gb HS SSD v2 | No | 4 |
4XB7A87202 | BURK | ThinkSystem 3.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD | Support | 4 |
4XB7A17137 | BA4W | ThinkSystem 3.5" S4620 480GB Mixed Use SATA 6Gb HS SSD | No | 4 |
4XB7A17138 | BA4X | ThinkSystem 3.5" S4620 960GB Mixed Use SATA 6Gb HS SSD | No | 4 |
4XB7A17139 | BA4Y | ThinkSystem 3.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD | No | 4 |
4XB7A17140 | BK7P | ThinkSystem 3.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD | No | 4 |
4XB7A17096 | B8JL | ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17098 | B8J0 | ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17099 | B8HR | ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17100 | B8HX | ThinkSystem 3.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A10243 | B48E | ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A10244 | B48F | ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD | No | 4 |
3.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD) | ||||
4XB7A90878 | BYLW | ThinkSystem 3.5" VA 240GB Read Intensive SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90879 | BYLJ | ThinkSystem 3.5" VA 480GB Read Intensive SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90880 | BYLY | ThinkSystem 3.5" VA 960GB Read Intensive SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90881 | BYLZ | ThinkSystem 3.5" VA 1.92TB Read Intensive SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90882 | BYM0 | ThinkSystem 3.5" VA 3.84TB Read Intensive SATA 6Gb HS SSD v2 | No | 4 |
4XB7A90883 | BYM1 | ThinkSystem 3.5" VA 7.68TB Read Intensive SATA 6Gb HS SSD v2 | No | 4 |
4XB7A17118 | BA7K | ThinkSystem 3.5" S4520 240GB Read Intensive SATA 6Gb HS SSD | No | 4 |
4XB7A17119 | BA7L | ThinkSystem 3.5" S4520 480GB Read Intensive SATA 6Gb HS SSD | No | 4 |
4XB7A17120 | BA7M | ThinkSystem 3.5" S4520 960GB Read Intensive SATA 6Gb HS SSD | No | 4 |
4XB7A17121 | BA7N | ThinkSystem 3.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD | No | 4 |
4XB7A17122 | BK7F | ThinkSystem 3.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD | No | 4 |
4XB7A17123 | BK7G | ThinkSystem 3.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD | No | 4 |
4XB7A38276 | BCTH | ThinkSystem 3.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A38277 | BCTJ | ThinkSystem 3.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A38278 | BCTK | ThinkSystem 3.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A38279 | BCTL | ThinkSystem 3.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A38281 | BCTM | ThinkSystem 3.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17081 | B8JB | ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17082 | B8J9 | ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17083 | B8JC | ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17084 | B8HZ | ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17085 | B8HQ | ThinkSystem 3.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A17086 | B8J3 | ThinkSystem 3.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A10158 | B2X7 | ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A10159 | B2X8 | ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD | No | 4 |
4XB7A10160 | B2X9 | ThinkSystem 3.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD | No | 4 |
Part number | Feature code |
Description | SED support |
Max Qty |
---|---|---|---|---|
M.2 SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD) | ||||
4XB7A89422 | BYF7 | ThinkSystem M.2 ER3 240GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A90049 | BYF8 | ThinkSystem M.2 ER3 480GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A90230 | BYF9 | ThinkSystem M.2 ER3 960GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A90105 | BXMK | ThinkSystem M.2 ER2 240GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A90106 | BXMJ | ThinkSystem M.2 ER2 480GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A82286 | BQ1Z | ThinkSystem M.2 5400 PRO 240GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A82287 | BQ1Y | ThinkSystem M.2 5400 PRO 480GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
4XB7A82288 | BQ20 | ThinkSystem M.2 5400 PRO 960GB Read Intensive SATA 6Gb NHS SSD | Support | 2 |
7N47A00129 | AUUL | ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
7N47A00130 | AUUV | ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
7SD7A05703 | B11V | ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
4XB7A14048 | B5UP | ThinkSystem M.2 5100 960GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
4XB7A17071 | B8HS | ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
4XB7A17073 | B919 | ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
4XB7A17074 | B8JJ | ThinkSystem M.2 5300 960GB SATA 6Gbps Non-Hot Swap SSD | No | 2 |
Internal backup units
The server does not supports any internal backup units, such as tape drives or RDX drives. External backup units are available as described in the External backup units section.
Optical drives
The server supports the external USB optical drive listed in the following table.
Part number | Feature code | Description |
---|---|---|
7XA7A05926 | AVV8 | ThinkSystem External USB DVD RW Optical Disk Drive |
The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.
I/O expansion
The server supports a total of up to 4 PCIe 4.0 slots (3 with rear access, 1 internal for a RAID adapter or HBA) plus a dedicated OCP 3.0 SFF slot for networking. Slot availability is based on riser selection.
- Slot 1: PCIe 4.0 x16 LP or FHHL
- Slot 2: PCIe 4.0 x16 LP (not present if slot 1 is FHHL or rear drive bays are present)
- Slot 3: PCIe 4.0 x16 LP (not present if rear drive bays are present)
- Slot 4: PCIe 4.0 x8 LP (internal slot; physically a x16 slot)
The following figure shows the locations of the rear-accessible slots for each configuration selection. The OCP slot in located in the lower-left corner.
The slots and riser cards are as follows:
- Riser 1: Slot 1 (PCIe x16)
- Slot 1: Low Profile or FHHL, PCIe 4.0 x16 slot
- Riser 2: Slots 2 & 3 (each PCIe x16)
- Slot 2: Low Profile, PCIe 4.0 x16 (only available in 3x LP slot configuration)
- Slot 3: Low Profile, PCIe 4.0 x16 (not available in configurations with rear drive bays)
- Internal Riser: Slot 4 (PCIe x8)
- Low Profile PCIe 4.0 x8 slot for internal drive controller (physically a x16 slot)
The riser cards and slot brackets used to provide the above slot combinations in configure-to-order (CTO) configurations are listed in the following table.
Tip: It is also possible to not have any slot selections, in which case slot fillers will be derived in the configurator. Slots can be added later as field upgrades using option part numbers.
Feature code |
Description | Maximum Supported |
Purpose |
---|---|---|---|
Riser 1 | |||
B5VV | ThinkSystem SR635/SR655 x16 PCIe Riser1 | 1 | Riser for slot 1 |
B5WZ | ThinkSystem SR635/SR655 MS FH Riser BKT | 1 | FHHL slot bracket for slot 1 |
B5WD | ThinkSystem SR635 MS LP Riser BKT Slot1 | 1 | Low Profile slot bracket for slot 1 |
Riser 2 | |||
B5W0 | ThinkSystem SR635/SR655 x16/x16 PCIe Riser2 (BF) | 1 | Riser for slots 2 & 3 |
B5X4 | ThinkSystem SR635 MS LP+LP BF Riser BKT | 1 | Low Profile brackets for slots 2 & 3 |
B715 | ThinkSystem SR635 MS LP Riser BKT Slot3 | 1 | Low Profile bracket for slot 3 |
Internal | |||
B5VW | ThinkSystem SR635/SR655 x8 PCIe Internal Riser | 1 | Riser for Internal slot |
B5WN | ThinkSystem SR635/SR655 Internal Riser BKT | 1 | Internal slot bracket |
Slot configurations can also be ordered as field upgrades using option part numbers, as listed in the following table.
Part number | Description | Maximum Supported |
---|---|---|
4XH7A09835 |
ThinkSystem SR635/SR655 x16 PCIe 1U Riser 1 Kit
|
1 |
4XH7A09836 |
ThinkSystem SR635/SR655 x16/x16 PCIe Riser2 LP Kit
|
1 |
4XH7A09843 |
ThinkSystem SR635/SR655 x8 PCIe Internal Riser Kit
|
1 |
Network adapters
The server has a dedicated OCP 3.0 SFF slot with PCIe 4.0 x16 host interface. See Figure 3 for the location of the OCP slot.
The following table lists the supported OCP adapters. One port can optionally be shared with the ASPEED management processor for Wake-on-LAN and NC-SI support. Only 1 OCP card can be installed in the server.
Part number | Feature code | Description |
---|---|---|
Gigabit | ||
4XC7A08235 | B5T1 | ThinkSystem Broadcom 5719 1GbE RJ45 4-port OCP Ethernet Adapter |
4XC7A88428 | BW97 | ThinkSystem Intel I350 1GbE RJ45 4-Port OCP Ethernet Adapter V2 |
4XC7A08277 | B93E | ThinkSystem Intel I350 1GbE RJ45 4-port OCP Ethernet Adapter |
10 GbE | ||
4XC7A08236 | B5ST | ThinkSystem Broadcom 57416 10GBASE-T 2-port OCP Ethernet Adapter |
4XC7A08239 | B5SS | ThinkSystem Broadcom 57416 10GBASE-T 2-port + 5720 1GbE 2-port OCP Ethernet Adapter |
4XC7A08240 | B5T4 | ThinkSystem Broadcom 57454 10GBASE-T 4-port OCP Ethernet Adapter |
4XC7A08278 | BCD5 | ThinkSystem Intel X710-T2L 10GBASE-T 2-port OCP Ethernet Adapter |
4XC7A80268 | BPPY | ThinkSystem Intel X710-T4L 10GBase-T 4-Port OCP Ethernet Adapter |
4XC7A08310 | BB8U | ThinkSystem Marvell QL41132 10GBASE-T 2-port OCP Ethernet Adapter |
25 GbE | ||
4XC7A08237 | B5SZ | ThinkSystem Broadcom 57414 10/25GbE SFP28 2-Port OCP Ethernet Adapter |
4XC7A08242 | B5SV | ThinkSystem Broadcom 57454 10/25GbE SFP28 4-port OCP Ethernet Adapter |
4XC7A80567 | BPPW | ThinkSystem Broadcom 57504 10/25GbE SFP28 4-Port OCP Ethernet Adapter |
4XC7A08294 | BCD4 | ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-Port OCP Ethernet Adapter |
4XC7A80269 | BP8L | ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-Port OCP Ethernet Adapter |
4XC7A08246 | B5T2 | ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port OCP Ethernet Adapter |
4XC7A62582 | BE4T | ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-port OCP Ethernet Adapter |
4XC7A08264 | B5SW | ThinkSystem Marvell QL41232 10/25GbE SFP28 2-Port OCP Ethernet Adapter |
Installation & removal: Before installing or removing an OCP adapter, power off your server and disconnect power cords first. See Support tip HT509768 for details.
For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet
The following table lists additional supported network adapters that can be installed in the regular PCIe slots.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
Gigabit Ethernet | ||||
7ZT7A00484 | AUZV | ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter | 1, 3, 2 | 3 |
7ZT7A00482 | AUZX | ThinkSystem Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter | 1, 3, 2 | 3 |
7ZT7A00533 | AUZZ | ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | 1, 3, 2* | 3 |
7ZT7A00534 | AUZY | ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | 1, 3, 2 | 3 |
7ZT7A00535 | AUZW | ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | 1, 3, 2 | 3 |
10 GbE | ||||
7ZT7A00496 | AUKP | ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter | 1, 3, 2 | 3 |
4XC7A08245 | B5SU | ThinkSystem Broadcom 57454 10GBASE-T 4-port PCIe Ethernet Adapter | 1, 3, 2* | 3 |
00MM860 | ATPX | Intel X550-T2 Dual Port 10GBase-T Adapter | 1, 3, 2 | 3 |
7ZT7A00537 | AUKX | ThinkSystem Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter | 1, 3, 2* | 3 |
4XC7A80266 | BNWL | ThinkSystem Intel X710-T2L 10GBase-T 2-Port PCIe Ethernet Adapter | 1, 3, 2 | 3 |
4XC7A79699 | BMXB | ThinkSystem Intel X710-T4L 10GBase-T 4-Port PCIe Ethernet Adapter | 1, 3, 2 | 3 |
4XC7A08225 | B31G | ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter | 1, 3, 2 | 3 |
25 GbE | ||||
4XC7A08238 | B5T0 | ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter | 1, 3, 2* | 3 |
4XC7A08316 | BD49 | ThinkSystem Broadcom 57454 10/25GbE SFP28 4-port PCIe Ethernet Adapter V2 | 1* | 1† |
4XC7A80566 | BNWM | ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port PCIe Ethernet Adapter | 1 | 1† |
4XC7A08295 | BCD6 | ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 1, 3, 2* | 3 |
4XC7A80267 | BP8M | ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-Port PCIe Ethernet Adapter | 1 | 1† |
4XC7A08270 | B652 | ThinkSystem Marvell QL41232 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 1, 3, 2* | 3 |
4XC7A08249 | B653 | ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter | 1, 3, 2* | 3 |
4XC7A62580 | BE4U | ThinkSystem Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 1, 3, 2* | 3 |
100 GbE | ||||
4XC7A08297 | BK1J | ThinkSystem Broadcom 57508 100GbE QSFP56 2-port PCIe 4 Ethernet Adapter | 1, 3, 2* | 3** |
4XC7A08248 | B8PP | ThinkSystem Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe Ethernet Adapter | 1, 3, 2* | 3** |
InfiniBand | ||||
4C57A14177 | B4R9 | ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter | 1, 3, 2* | 3** |
4C57A14178 | B4RA | ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter | 1, 3, 2* | 3** |
4C57A15326 | B4RC | ThinkSystem Mellanox ConnectX-6 HDR/200GbE QSFP56 1-port PCIe 4 VPI Adapter | 1, 3, 2* | 3** |
* Not supported in slot 2 when a 280W processor is installed
** See thermal requirements below
† In the SR635, this adapter requires a full-height bracket and must be installed in a full-height slot. The use of a low-profile bracket and slot is not supported.
The following thermal requirement apply to HDR/HDR100 InfiniBand and 100/200Gb Ethernet adapters:
- The high performance cooling fans must be installed. See the Cooling section for details.
- Ambient temperature cannot be greater than 35°C (if the processor TDP is 155W or lower) or 30°C (for 180W or higher processors)
For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet
Fibre Channel host bus adapters
The following table lists the Fibre Channel HBAs supported by the SR635.
Note that the Emulex LPe35000 adapters are supported either with EPYC 7002 "Rome" processors or with EPYC 7003 "Milan" processors, as indicated in the table.
Part number |
Feature code |
Description | EPYC 7002 |
EPYC 7003 |
Slots supported |
Maximum supported |
---|---|---|---|---|---|---|
32 Gb Fibre Channel HBAs | ||||||
4XC7A08250 | B5SX | ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter | Yes | No | 1, 3, 2* | 3 |
4XC7A08251 | B5SY | ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter | Yes | No | 1, 3, 2* | 3 |
4XC7A76498 | BJ3G | ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter v2 | No | Yes | 1, 3, 2* | 3 |
4XC7A76525 | BJ3H | ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter V2 | No | Yes | 1, 3, 2* | 3 |
4XC7A08279 | BA1G | ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel Adapter | Yes | Yes | 1, 3, 2* | 3 |
4XC7A08276 | BA1F | ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel Adapter | Yes | Yes | 1, 3, 2* | 3 |
7ZT7A00516 | AUNS | ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter | Yes | Yes | 1, 3, 2* | 3 |
7ZT7A00518 | AUNU | ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter | Yes | Yes | 1, 3, 2* | 3 |
16 Gb Fibre Channel HBAs | ||||||
01CV840 | ATZV | Emulex 16Gb Gen6 FC Dual-port HBA | Yes | Yes | 1, 3, 2* | 3 |
01CV830 | ATZU | Emulex 16Gb Gen6 FC Single-port HBA | Yes | Yes | 1, 3, 2* | 3 |
01CV760 | ATZC | QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | Yes | Yes | 1, 3, 2* | 3 |
01CV750 | ATZB | QLogic 16Gb Enhanced Gen5 FC Single-port HBA | Yes | Yes | 1, 3, 2* | 3 |
* Not supported in slot 2 when a 280W processor is installed
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba
SAS adapters for external storage
The following table lists SAS HBAs and RAID adapters supported by SR635 server for use with external storage.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
SAS HBAs | ||||
7Y37A01090 | AUNR | ThinkSystem 430-8e SAS/SATA 12Gb HBA | 1, 3, 2 | 3 |
7Y37A01091 | AUNN | ThinkSystem 430-16e SAS/SATA 12Gb HBA | 1, 3, 2 | 3 |
4Y37A78837 | BNWK | ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA | 1, 3, 2 | 3 |
4Y37A09724 | B8P7 | ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA | 1, 3, 2 | 3 |
External RAID adapters | ||||
7Y37A01087 | AUNQ | ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | 1, 3, 2 | 3* |
4Y37A78836 | BNWJ | ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter | 1, 3, 2 | 3* |
* See configuration rules below
Mixing storage adapter families: The following HBA/RAID adapter combinations are supported:
- X30 external adapters with other X30 adapters (internal or external)
- X40 external adapters with other X40 adapters (internal or external)
- X40 external adapters with X350 internal adapters
The following HBA/RAID adapter combinations are not supported:
- X30 adapters (internal or external) with X40 adapters (internal or external)
- X30 adapters (internal or external) with X350 internal adapters
Configuration rules
The RAID 930-8e and RAID 940-8e use a flash power module (supercap), which can be installed in one of 3 locations as shown in the following figure.
Figure 12. Location of all three supercaps in the SR635 (2.5-inch drive configuration)
The number of supercap locations is reduced depending on installed components:
- For configurations with 2.5-inch front drives and no mid drive cage, 3x 930/940-8e adapters and supercaps can be installed (locations 1, 2, and 3).
- For configurations with 2.5-inch front drives and a mid drive cage installed, 1x 930/940-8e adapter and supercap can be installed (location 3 only).
- For configurations with 3.5-inch front drives, and no mid drive cage, 2x 930/940-8e adapters and supercaps can be installed (location 1 and 2; location 3 is not present).
- For configurations with 3.5-inch front drives and a mid drive cage installed, no 930/940-8e adapters and supercaps can be installed.
- If any internal RAID adapters with flash power modules are installed, the maximum number of 930/940-8e adapters supported is further reduced by that number.
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters and RAID adapters categories:
https://lenovopress.com/servers/options/hba
https://lenovopress.com/servers/options/raid
The following table compares the specifications of the external SAS HBAs and RAID adapters.
Feature | 430-8e | 430-16e | 930-8e |
---|---|---|---|
Adapter type | HBA | HBA | External RAID |
Part number | 7Y37A01090 | 7Y37A01091 | 7Y37A01087 |
Controller chip | LSI SAS3408 | LSI SAS3416 | LSI SAS3516 |
Broadcom equivalent | HBA 9400-8e | HBA 9400-16e | MegaRAID 9480-8e |
Host interface | PCIe 3.0x8 | PCIe 3.0x8 | PCIe 3.0x8 |
Port interface | 12 Gb SAS | 12 Gb SAS | 12 Gb SAS |
Number of ports | 8 | 16 | 8 |
Port connectors | 2x Mini-SAS HD SFF8644 | 4x Mini-SAS HD SFF8644 | 2x Mini-SAS HD SFF8644 |
Drive interface | SAS/SATA | SAS/SATA | SAS,SATA |
Drive type | HDD/SSD/SED* | HDD/SSD/SED* | HDD,SED,SSD |
Hot-swap drives | Yes | Yes | Yes |
Maximum devices | 1024 | 1024 | 216 |
RAID levels | None | None | 0/1/10/5/50/6/60 |
JBOD mode | Yes | Yes | Yes |
Cache | None | None | 4GB (Standard) |
CacheVault cache protection | None | None | Yes (Flash) |
Performance Accelerator (FastPath) | No | No | Yes |
SSD Caching (CacheCade Pro 2.0) | No | No | No |
SED support* | Yes | Yes | Yes |
* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
Flash storage adapters
The SR635 supports the PCIe Flash Storage adapters listed in the following table.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
Mainstream NVMe PCIe Adapters - Optimized for mixed-intensive application workloads with an endurance of 3-5 DWPD. | ||||
4XB7A38234 | BCGJ | ThinkSystem HHHL Kioxia CM5-V 1.6TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1, 3, 2 | 3 |
4XB7A38237 | BCGK | ThinkSystem HHHL Kioxia CM5-V 3.2TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1, 3, 2 | 3 |
4XB7A38240 | BCGL | ThinkSystem HHHL Kioxia CM5-V 6.4TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1, 3, 2 | 3 |
4XB7A14075 | B8JH | ThinkSystem HHHL PM1735 1.6TB Mainstream NVMe PCIe 4.0 x8 Flash Adapter | 1, 3, 2 | 3 |
4XB7A14076 | B8HW | ThinkSystem HHHL PM1735 3.2TB Mainstream NVMe PCIe 4.0 x8 Flash Adapter | 1, 3, 2 | 3 |
4XB7A14077 | B96M | ThinkSystem HHHL PM1735 6.4TB Mainstream NVMe PCIe4.0 x8 Flash Adapter | 1, 3, 2 | 3 |
4XB7A08520 | B32L | ThinkSystem HHHL Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1, 3, 2 | 3 |
4XB7A08521 | B32M | ThinkSystem HHHL Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1, 3, 2 | 3 |
For details about these adapters, see the Lenovo Press product guides in the Flash Adapters category:
https://lenovopress.com/servers/options/ssdadapter
Configuration rules
The following configuration requirements must be met when installing flash storage adapters:
- GPU adapters are not supported
- Maximum processor TDP is 155W
- Performance fans are required and will be derived by the configurator for configure-to-order builds.
- When adding Flash adapters as field upgrades, you will be required to replace all standard fans with performance fan modules. The ordering part number is listed in the following table - you will be required to order 7 fans.
Part number | Feature code | Description | Quantity required |
---|---|---|---|
4F17A14483 | B5X0 | ThinkSystem SR635 Performance Fan Module | 7 |
GPU adapters
The SR635 supports the following graphics processing units (GPUs).
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
CTO only | BP05 | ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU | 1, 3, 2 | 3 |
4X67A81547 | BQZT | ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU w/o CEC | 1, 3, 2 | 3 |
4X67A14926 | B4YB | ThinkSystem NVIDIA T4 16GB PCIe Passive GPU | 1, 3, 2 | 3 |
4X67A11584 | B31D | ThinkSystem NVIDIA Quadro P620 2GB PCIe Active GPU | 1, 3, 2 | 3 |
For information about these GPUs, see the ThinkSystem GPU Summary, available at:
https://lenovopress.com/lp0768-thinksystem-thinkagile-gpu-summary
Configuration rules
The following configuration requirements must be met when installing GPUs:
- Some NVIDIA A Series GPUs are available as two feature codes, one with a CEC chip and one without a CEC chip (ones without the CEC chip have "w/o CEC" in the name). The CEC is a secondary Hardware Root of Trust (RoT) module that provides an additional layer of security, which can be used by customers who have high regulatory requirements or high security standards. NVIDIA uses a multi-layered security model and hence the protection offered by the primary Root of Trust embedded in the GPU is expected to be sufficient for most customers. The CEC defeatured products still offer Secure Boot, Secure Firmware Update, Firmware Rollback Protection, and In-Band Firmware Update Disable. Specifically, without the CEC chip, the GPU does not support Key Revocation or Firmware Attestation. CEC and non-CEC GPUs of the same type of GPU can be mixed in field upgrades.
- All GPUs installed must be identical
- Rear drive bays and mid-chassis drive bays are not supported.
- Flash storage adapters are not supported.
- 1100W power supplies (or in some configurations, 750W power supplies) are required.
- If the intrusion switch is installed, then only two GPUs can be installed, in slots 2 and 3. The intrusion switch and a GPU in slot 1 are mutually exclusive.
Additional rules when installing T4 GPUs:
- With two GPUs installed, processor TDP greater than 200W not supported
- If ambient temperature is 35°C, then processor TDP greater than 120W not supported
- If ambient temperature is 30°C, then processor TDP greater than 200W not supported
- With three GPUs installed, processor TDP greater than 120W not supported
- The following additional drive backplane rules apply if 3 GPUs are installed (rules do not apply if only 2 GPUs installed):
- 3.5-inch drive bay backplane (AUW8) is fully supported
- 8x 2.5-inch drive backplane (B7K3) supported, however 2 drive bays (6, 7) must be empty
- 6x 2.5-inch SAS/SATA + 4x AnyBay backplane (AUW9) supported, however all AnyBay bays (6, 7, 8, 9) must be empty
- 10x 2.5-inch AnyBay backplane (B5VS), however 4 bays (6, 7, 8, 9) must be empty
- Ambient temperature great than 30°C is not supported
- Processor TDP greater than 120W is not supported
Additional rules when installing any quantity of P620 GPUs:
- All front drive bay configurations are supported
- Ambient temperature great than 35°C is not supported
- Processor TDP greater than 240W is not supported
GPU field upgrades
When ordering GPUs as part of a CTO configuration, the necessary cooling features are automatically selected as part of the order. However when ordering the GPUs as field upgrades, you will need to also order 7 performance fans which will replace the standard fans already installed. 7 part numbers will need to be ordered per server.
Part number | Description | Quantity required |
---|---|---|
4F17A14483 | ThinkSystem SR635 Performance Fan Module | 7 |
When a GPU is added as a field upgrade, all empty DIMM slots must have a dummy DIMM blank installed in each DIMM slot, to ensure the optimal air flow. Ordering information is in the following table.
Part number | Description | Quantity required |
---|---|---|
4M27A11810 | ThinkSystem Dummy DIMM Package Kit (contains 24 dummy memory DIMMs) |
1 |
Cooling
The SR635 server has seven 40 mm dual-rotor hot-swap variable-speed fans and either 6 or 7 fans are standard depending on the configuration. The fans are dual-rotor counter-rotating units, which means that the fans have two separate propellors, one in front of the other, and that the propellors rotate in opposite directions. The server offers N+1 redundancy. The server also has one additional fan integrated in each of the two power supplies.
Under all of the following conditions, only 6 fans are required:
- No M.2 Module
- No internal riser slot
- No mid drive bays
- No rear drives
- No GPUs
For all other configurations, all 7 fans are required.
Part number | Feature code | Description | Maximum supported |
---|---|---|---|
4F17A12358 | B5X1 | ThinkSystem SR635 1U Fan Module | 7 |
4F17A14483 | B5X0 | ThinkSystem SR635 Performance Fan Module | 7 |
Some configurations, such as the use of high-TDP processors, GPUs, flash storage adapters, mid drive or rear drives, or Ethernet/InfiniBand adapters of 100Gb or higher, will require the use of high performance fans which have higher RPMs. For configure-to-order builds, the DCSC configurator will automatically select the required fans. For field upgrades, the option part numbers may include the upgraded components when they are needed, or you may need to order the performance fans separately.
See these sections for details:
Power supplies
The server supports up to two redundant hot-swap power supplies.
The power supply choices are listed in the following table. Both power supplies used in server must be identical.
Tip: Use Lenovo Capacity Planner to determine exactly what power your server needs:
https://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp
Part number | Feature code |
Description | Maximum supported |
110V AC | 220V AC | 240V DC China only |
-48V DC |
---|---|---|---|---|---|---|---|
AC power input | |||||||
7N67A00882 | AVWC | ThinkSystem 550W(230V/115V) Platinum Hot-Swap Power Supply | 2 | Yes | Yes | Yes | No |
7N67A00883 | B6XT | ThinkSystem 750W(230/115V) Platinum Hot-Swap Power Supply | 2 | Yes | Yes | Yes | No |
7N67A00884 | B6XS | ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply | 2 | No | Yes | Yes | No |
4P57A82020 | BR1Y | ThinkSystem V1 750W (230Vac) Titanium Hot Swap Power Supply | 2 | No | Yes | Yes | No |
7N67A00885 | AVWF | ThinkSystem 1100W (230V/115V) Platinum Hot-Swap Power Supply | 2 | Yes | Yes | Yes | No |
-48V DC input power | |||||||
4P57A15363* | B4Z5* | ThinkSystem 1100W -48V DC Power Supply | 2 | No | No | No | Yes |
* -48V DC power supply is only available via Special Bid
Dual-voltage power supplies are auto-sensing and support both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. For China customers, all AC power supplies support 240V DC.
All supported AC power supplies have a C14 connector. The -48V DC power supply has a Positronic PLB3W3M1000/AA connector.
Power supply options do not include a line cord.
For server configurations, the inclusion of a power cord is model dependent. Configure-to-order models can be configured without power cords if desired.
Power cords
Line cords and rack power cables with C13 connectors can be ordered as listed in the following table.
115V customers: If you plan to use the 1100W power supply with a low-range (100-127V) power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with low-range power.
Part number | Feature code | Description |
---|---|---|
Rack cables - C13 to C14 | ||
SL67B08593 | BPHZ | 0.5m, 10A/100-250V, C13 to C14 Jumper Cord |
00Y3043 | A4VP | 1.0m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08367 | B0N5 | 1.0m, 13A/100-250V, C13 to C14 Jumper Cord |
39Y7937 | 6201 | 1.5m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08368 | B0N6 | 1.5m, 13A/100-250V, C13 to C14 Jumper Cord |
4L67A08365 | B0N4 | 2.0m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08369 | 6570 | 2.0m, 13A/100-250V, C13 to C14 Jumper Cord |
4L67A08366 | 6311 | 2.8m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08370 | 6400 | 2.8m, 13A/100-250V, C13 to C14 Jumper Cord |
39Y7932 | 6263 | 4.3m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08371 | 6583 | 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable |
Rack cables - C13 to C14 (Y-cable) | ||
00Y3046 | A4VQ | 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable |
00Y3047 | A4VR | 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable |
Rack cables - C13 to C20 | ||
39Y7938 | 6204 | 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable |
Rack cables - C13 to C20 (Y-cable) | ||
47C2491 | A3SW | 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable |
47C2492 | A3SX | 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable |
47C2493 | A3SY | 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable |
47C2494 | A3SZ | 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable |
Line cords | ||
39Y7930 | 6222 | 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord |
81Y2384 | 6492 | 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord |
39Y7924 | 6211 | 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord |
81Y2383 | 6574 | 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord |
69Y1988 | 6532 | 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord |
81Y2387 | 6404 | 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord |
39Y7928 | 6210 | 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord |
81Y2378 | 6580 | 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord |
39Y7918 | 6213 | 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord |
81Y2382 | 6575 | 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord |
39Y7917 | 6212 | 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord |
81Y2376 | 6572 | 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord |
39Y7927 | 6269 | 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord |
81Y2386 | 6567 | 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord |
39Y7920 | 6218 | 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord |
81Y2381 | 6579 | 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord |
39Y7921 | 6217 | 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord |
81Y2380 | 6493 | 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord |
46M2593 | A1RE | 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord |
4L67A08362 | 6495 | 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord |
39Y7926 | 6335 | 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord |
39Y7922 | 6214 | 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord |
81Y2379 | 6576 | 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord |
39Y7925 | 6219 | 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord |
81Y2385 | 6494 | 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord |
39Y7919 | 6216 | 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord |
81Y2390 | 6578 | 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord |
23R7158 | 6386 | 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord |
81Y2375 | 6317 | 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord |
81Y2374 | 6402 | 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord |
4L67A08363 | AX8B | 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord |
81Y2389 | 6531 | 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord |
81Y2388 | 6530 | 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord |
39Y7923 | 6215 | 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord |
81Y2377 | 6577 | 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord |
90Y3016 | 6313 | 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord |
46M2592 | A1RF | 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord |
00WH545 | 6401 | 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord |
4L67A08359 | 6370 | 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord |
4L67A08361 | 6373 | 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord |
4L67A08360 | AX8A | 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord |
For the -48V DC Power Supply, the following power cable is supported.
Part number | Feature code | Description |
---|---|---|
CTO only | B93F | ThinkSystem 2.5m,DC Cable |
Integrated virtualization
The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.
You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/
Systems management
The server contains an integrated service processor which provides advanced control, monitoring, and alerting functions. The service processor is based on the ASPEED AST2500 baseboard management controller (BMC).
- Local management
- Remote management
- Lenovo XClarity Administrator
- Lenovo XClarity Provisioning Manager Lite
- Lenovo XClarity Essentials
- Lenovo XClarity Energy Manager
Local management
The SR635 offers a front operator panel with key LED status indicators, as shown in the following figure.
Tip: The Network LED only shows network activity of the installed OCP network adapter.
The server offers light path diagnostics. If an environmental condition exceeds a threshold or if a system component fails, the ASPEED service processor lights LEDs inside the server to help you diagnose the problem and find the failing part. The SR635 has fault LEDs next to the following components:
- Each memory DIMM
- Each drive bay
- Each system fan
- Each power supply
The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access the service processor.
Remote management
Remote server management is provided through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3 (traps and gets)
- Redfish support to the Redfish Schema 2018.1 (DMTF DSP0266 1.5.0 compliant)
- Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for the device being used - laptop, tablet, phone) with NLS support
Remote connectivity is provided by a dedicated 1Gb Ethernet management port (see the locations of ports at the rear of the server in the Components and connectors section). Remote management can also be performed via the first port of the installed OCP adapter using the shared management capability of the adapter via NC-SI. NC-SI connectivity is 10/100 Mbps Ethernet.
IPMI via the Ethernet port (IPMI over LAN) is supported, however it is disabled by default. For CTO orders you can specify whether you want to the feature enabled or disabled in the factory, using the feature codes listed in the following table.
Part number | Feature code | Description |
---|---|---|
CTO only | B7XZ | Disable IPMI-over-LAN (default) |
CTO only | B7Y0 | Enable IPMI-over-LAN |
A virtual presence (iKVM remote control and virtual media) capability also comes standard in the server for remote server management.
The remote control functions include the following:
- Remotely viewing video with graphics resolutions up to 1920x1080 at 60 Hz and 32 bits per pixel, regardless of the system state
- Remotely accessing the server using the keyboard and mouse from a remote client
- Full remote administration with seamless access from UEFI POST through to operating system load
- OS independent - no drivers or OS agents required
- Support for up to four remote users simultaneously
The remote media functions include:
- USB 2.0 compliant connectivity
- Up to four simultaneously mounted diskette, HDD, CD, DVD, USB flash drive, or image files
- Optional encryption on connections
- Requires Java Runtime Environment (JRE) 1.4.2 or later
- Can be used as a boot device
- Persistent session across system reset (but not across AC power loss)
Lenovo XClarity Administrator
Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. Lenovo XClarity Administrator provides agent-free hardware management for ThinkSystem servers, in addition to other Lenovo servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.
On the SR635, XClarity Administrator v3.2.0 or later is required for full firmware-update support, managed authentication, and remote control. The baseboard management controller firmware should be v3.56 or later.
Lenovo XClarity Administrator supports the following functions on the SR635:
- Asset management
- Hardware monitoring
- Hardware management
- Configuration management
- Firmware compliance and updates
- Device authentication using an LDAP server
- Remote control
- Warranty status
- Automatic problem notification (call home)
For details of these functions, see the paper Introduction to Managing ThinkSystem SR635 and SR655 Servers with Lenovo XClarity Administrator, available from https://lenovopress.com/lp1419
The following functions are not supported:
- Network interfaces using IPv6 link-Local Address (LLA) (only IPv4 addresses and global unicast IPv6 address are supported)
- Server configuration other than BIOS configuration using configuration patterns
- Windows OS device driver updates
- Operating system deployment
- Virtually reseating a server
- Single sign-on to the management controller interface
For more information about Lenovo XClarity Administrator, including ordering part numbers, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator
Lenovo XClarity Provisioning Manager Lite
Lenovo XClarity Provisioning Manager Lite (LXPM Lite) v2 is an embedded application for system setup and firmware upgrades. The tool is accessed during system boot by pressing F11 when prompted.
The software tool provides the following functions:
- Easy-to-use, language-selectable graphical interface
- Integrated help system
- Automatic hardware detection
- Ability to install an operating system and device drivers either in an unattended mode or manually
- Ability to clone the settings in one server to other similarly configured Lenovo servers
- Supports RAID setup
- Diagnostics for memory test, hard disk drive test, and RAID log collection.
The LXPM Lite user interface is shown in the following figure.
Figure 14. Lenovo XClarity Provisioning Manager Lite user interface (pre-production server)
For more information about LXPM Lite, see the following support page:
https://datacentersupport.lenovo.com/us/en/solutions/HT507133
Lenovo XClarity Essentials
Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:
- Lenovo Essentials OneCLI
OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and drivers. It provides functions to collect full system health information (including health status), configure system settings, update BMC/UEFI firmware (in-band and out-of-band), and update drivers.
Note: OneCLI on the SR635 currently does not support firmware update of adapters. For UEFI settings, all OneCLI commands are supported. For BMC settings, OneCLI support is limited to network, ntp, dns, account commands and the following VPD parameters: VPD.Model, VPD.SerialNumber, VPD.AssetTag, VPD.UUID.
- Lenovo Essentials UpdateXpress
The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.
Note: UpdateXpress on the SR635 is currently limited to only support BMC and UEFI firmware updates.
- Lenovo Essentials Bootable Media Creator
The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.
For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center
Lenovo XClarity Energy Manager
Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less power management console that provides real time data and enables you to observe, plan and manage power and cooling for Lenovo servers. Using built-in intelligence, it identifies server power consumption trends and ideal power settings and performs cooling analysis so that you can define and optimize power-saving policies.
Lenovo XClarity Energy Manager offers the following capabilities:
- Monitors room, row, rack, and device levels in the data center
- Reports vital server information, such as power, temperature and resource utilization
- Monitors inlet temperature to locate hot spots, reducing the risk of data or device damage
- Provides finely-grained controls to limit platform power in compliance with IT policy
- Generates alerts when a user-defined threshold is reached
Note: In the SR635, system power capping function is not supported on Lenovo XClarity Energy Manager.
Lenovo XClarity Energy Manager is an optional software component that is licensed on a per managed node basis, that is, each managed server requires a license. To manage systems, a node license pack should be purchased. The following table lists the geo-specific Lenovo XClarity Energy Manager software license options.
Description | Part number (NA, AP, Japan)* |
Part number (EMEA, LA)** |
Quantity |
---|---|---|---|
Lenovo XClarity Energy Manager, 1 Node w/ 1 Yr S&S | 01DA225 | 01DA228 | 1 |
For more information, refer to the Lenovo XClarity Energy Manager web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem
Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.
For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp
Security
The SR635 server offers the following security features:
- Administrator and power-on password
- Integrated Trusted Platform Module (TPM) supporting TPM 2.0
- Optional Nationz TPM 2.0, available only in China (CTO only)
- Optional chassis intrusion switch (CTO only)
- Optional lockable front security bezel
The server is NIST SP 800-147B compliant.
The optional lockable front security bezel is shown in the following figure and includes a key that enables you to secure the bezel over the drives and system controls thereby reducing the chance of unauthorized or accidental access to the server.
Figure 15. Lockable front security bezel
The dimensions of the security bezel are:
- Width: 437 mm (17.2 in.)
- Height: 43 mm (1.3 in.)
- Width: 23 mm (0.9 in.)
The following table lists the security options for the SR635.
Part number | Feature code | Description |
---|---|---|
None* | B22N | ThinkSystem Nationz Trusted Platform Module v2.0 (China customers only) |
None* | B9V3 | ThinkSystem Intrusion Switch Cable |
7Z17A02581 | AUWR | ThinkSystem 1U Security Bezel |
* Not available as a field upgrade. The component is CTO or on pre-configured models only.
GPU support with the intrusion switch: If the intrusion switch is selected, then a GPU cannot be installed in slot 1.
Rack installation
The following table lists the rack installation options that are available for the server.
The VGA Upgrade Kit allows you to upgrade your server by adding a VGA video port to the front of the server (if the server does not already come with a front VGA port). When the front VGA is in use, the rear VGA port is automatically disabled.
Option | Feature Code | Description |
---|---|---|
Optional front VGA port | ||
4XH7A80465 | BMNW or BMNX* | ThinkSystem SR635 Front VGA Upgrade Kit v2 (adds a VGA port to the front of the server) |
4XH7A09849 | AUWU or B5TX* | ThinkSystem SR635 Front VGA Upgrade Kit (adds a VGA port to the front of the server) |
4-post rail kits | ||
B42B | ThinkSystem Toolless Friction Rail v2 | |
4M17A13564 | BK7W | ThinkSystem Toolless Friction Rail v2 |
7M27A05702 | AXCA | ThinkSystem Toolless Slide Rail |
7M27A05701 | AXCB | ThinkSystem Toolless Slide Rail Kit with 1U CMA |
Cable management arm | ||
7M27A05699 | B136 | ThinkSystem 1U CMA Upgrade Kit for Toolless Slide Rail |
* BMNX / B5TX is a 950mm cable for configurations with 3.5-inch drive bays in the front of the server; BMNW / AUWU is a 715mm cable for configurations with 2.5-inch drive bays in the front of the server. The related option part number contains both cables.
The following table summarizes the rail kit features and specifications.
Feature | ThinkSystem Toolless Slide Rail | ThinkSystem Toolless Friction Rail v2 |
---|---|---|
Part number | 7M27A05702 (optional CMA) 7M27A05701 (with CMA) |
4M17A13564 |
Rail type | Full-out slide (ball bearing) | Half-out slide (friction) |
Toolless installation | Yes | Yes |
Cable Management Arm (CMA) support |
Yes
|
No |
In-rack server maintenance | Yes | No |
1U PDU support | Yes | Yes |
0U PDU support | Limited* | Limited** |
Rack type | Lenovo and IBM 4-post, IEC standard-compliant |
Lenovo and IBM 4-post, IEC standard-compliant |
Mounting holes | Square or round | Square or round |
Mounting flange thickness | 2 mm - 3.3 mm (0.08 - 0.13 in.) |
2 mm - 3.3 mm (0.08 - 0.13 in.) |
Distance between front and rear mounting flanges |
610 mm - 864 mm (24 - 34 in.) |
610 mm - 864 mm (24 - 34 in.) |
Rail length*** | 730 mm (28.74 in.) | 751 mm (29.6 in.) |
* For 0U PDU support, the rack must be at least 1100 mm (43.31 in.) deep without a CMA, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** For 0U PDU support with the friction rail kit, the rack must be at least 1000 mm (39.37 in.) deep.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.
Rack shipment: The following restriction applies when shipping the SR635 in a rack:
- No 2.5-inch rear drive bays
Operating system support
The SR635 with EPYC 7003 processors supports the following operating systems:
- Microsoft Windows Server 2016
- Microsoft Windows Server 2019
- Microsoft Windows Server 2022
- Red Hat Enterprise Linux 8.3
- Red Hat Enterprise Linux 8.4
- Red Hat Enterprise Linux 8.5
- Red Hat Enterprise Linux 8.6
- Red Hat Enterprise Linux 8.7
- Red Hat Enterprise Linux 8.8
- Red Hat Enterprise Linux 8.9
- Red Hat Enterprise Linux 8.10
- Red Hat Enterprise Linux 9.0
- Red Hat Enterprise Linux 9.1
- Red Hat Enterprise Linux 9.2
- Red Hat Enterprise Linux 9.3
- Red Hat Enterprise Linux 9.4
- Red Hat Enterprise Linux 9.5
- SUSE Linux Enterprise Server 12 SP5
- SUSE Linux Enterprise Server 12 Xen SP5
- SUSE Linux Enterprise Server 15 SP2
- SUSE Linux Enterprise Server 15 SP3
- SUSE Linux Enterprise Server 15 SP4
- SUSE Linux Enterprise Server 15 SP5
- SUSE Linux Enterprise Server 15 SP6
- SUSE Linux Enterprise Server 15 Xen SP2
- SUSE Linux Enterprise Server 15 Xen SP3
- SUSE Linux Enterprise Server 15 Xen SP4
- SUSE Linux Enterprise Server 15 Xen SP5
- Ubuntu 22.04 LTS 64-bit
- Ubuntu 24.04 LTS 64-bit
- VMware ESXi 6.7 U3
- VMware ESXi 7.0 U2
- VMware ESXi 7.0 U3
- VMware ESXi 8.0
- VMware ESXi 8.0 U1
- VMware ESXi 8.0 U2
- VMware ESXi 8.0 U3
The SR635 with EPYC 7002 processors supports the following operating systems:
- Microsoft Windows Server 2016
- Microsoft Windows Server 2019
- Microsoft Windows Server 2022
- Red Hat Enterprise Linux 7.6
- Red Hat Enterprise Linux 7.7
- Red Hat Enterprise Linux 7.8
- Red Hat Enterprise Linux 7.9
- Red Hat Enterprise Linux 8.0
- Red Hat Enterprise Linux 8.1
- Red Hat Enterprise Linux 8.2
- Red Hat Enterprise Linux 8.3
- Red Hat Enterprise Linux 8.4
- Red Hat Enterprise Linux 8.5
- Red Hat Enterprise Linux 8.6
- Red Hat Enterprise Linux 8.7
- Red Hat Enterprise Linux 8.8
- Red Hat Enterprise Linux 8.9
- Red Hat Enterprise Linux 8.10
- Red Hat Enterprise Linux 9.0
- Red Hat Enterprise Linux 9.1
- Red Hat Enterprise Linux 9.2
- Red Hat Enterprise Linux 9.3
- Red Hat Enterprise Linux 9.4
- Red Hat Enterprise Linux 9.5
- SUSE Linux Enterprise Server 12 SP4
- SUSE Linux Enterprise Server 12 SP5
- SUSE Linux Enterprise Server 12 Xen SP4
- SUSE Linux Enterprise Server 12 Xen SP5
- SUSE Linux Enterprise Server 15 SP1
- SUSE Linux Enterprise Server 15 SP2
- SUSE Linux Enterprise Server 15 SP3
- SUSE Linux Enterprise Server 15 SP4
- SUSE Linux Enterprise Server 15 SP5
- SUSE Linux Enterprise Server 15 SP6
- SUSE Linux Enterprise Server 15 Xen SP1
- SUSE Linux Enterprise Server 15 Xen SP2
- SUSE Linux Enterprise Server 15 Xen SP3
- SUSE Linux Enterprise Server 15 Xen SP4
- SUSE Linux Enterprise Server 15 Xen SP5
- Ubuntu 22.04 LTS 64-bit
- Ubuntu 24.04 LTS 64-bit
- VMware ESXi 6.5 U3
- VMware ESXi 6.7 U3
- VMware ESXi 7.0
- VMware ESXi 7.0 U1
- VMware ESXi 7.0 U2
- VMware ESXi 7.0 U3
- VMware ESXi 8.0
- VMware ESXi 8.0 U1
- VMware ESXi 8.0 U2
- VMware ESXi 8.0 U3
For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide:
- SR635 with EPYC 7003: https://lenovopress.com/osig#servers=sr635-7y98-7y99-epyc-7003
- SR635 with EPYC 7002: https://lenovopress.com/osig#servers=sr635-7y98-7y99-epyc-7002
For configure-to-order configurations, the SR635 can be preloaded with VMware ESXi. Ordering information is listed in the following table.
Part number | Feature code | Description |
---|---|---|
CTO only | B6U0 | VMware ESXi 6.5 U3 (factory installed) |
CTO only | B88T | VMware ESXi 6.7 U3 (factory installed) |
CTO only | BE5E | VMware ESXi 7.0 U1 (Factory Installed) |
CTO only | BHSR | VMware ESXi 7.0 U2 (Factory Installed) |
CTO only | BMEY | VMware ESXi 7.0 U3 (Factory Installed) |
CTO only | BMT5 | VMware ESXi 8.0 (Factory Installed) |
CTO only | BQ8S | VMware ESXi 8.0 U1 (Factory Installed) |
CTO only | BYC7 | VMware ESXi 8.0 U2 (Factory Installed) |
Configuration rule:
- An ESXi preload cannot be selected if the configuration includes an NVIDIA GPU (ESXi preload cannot include the NVIDIA driver)
You can download supported VMware vSphere hypervisor images from the following web page and install it using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/
Physical and electrical specifications
The SR635 has the following overall physical dimensions, excluding components that extend outside the standard chassis, such as EIA flanges, front security bezel (if any), and power supply handles:
- Width: 440 mm (17.3 inches)
- Height: 43 mm (1.7 inches)
- Depth: 755 mm (29.7 inches)
The following table lists the detailed dimensions. See the figure below for the definition of each dimension.
Dimension | Description |
---|---|
482 mm | Xa = Width, to the outsides of the front EIA flanges |
435 mm | Xb = Width, to the rack rail mating surfaces |
440 mm | Xc = Width, to the outer most chassis body feature |
43 mm | Ya = Height, from the bottom of chassis to the top of the chassis |
714 mm | Za = Depth, from the rack flange mating surface to the rearmost I/O port surface |
721 mm | Zb = Depth, from the rack flange mating surface to the rearmost feature of the chassis body |
743 mm | Zc = Depth, from the rack flange mating surface to the rearmost feature such as power supply handle |
35 mm | Zd = Depth, from the forwardmost feature on front of EIA flange to the rack flange mating surface |
47 mm | Ze = Depth, from the front of security bezel (if applicable) or forwardmost feature to the rack flange mating surface |
The shipping (cardboard packaging) dimensions of the SR635 are as follows:
- Width: 587 mm (23.1 inches)
- Height: 225 mm (8.9 inches)
- Depth: 998 mm (39.3 inches)
The server has the following weight:
- Maximum weight: 19.2 kg (42.3 lb)
Electrical specifications for AC power supplies:
- Electrical - Input voltage
- 100 - 127 (nominal) V AC, 50 Hz or 60 Hz
- 200 - 240 (nominal) V AC, 50 Hz or 60 Hz
- 180 - 300 V DC (China only)
- Inlet current:
- 100-127 V:
- 550W power supply: 6.2 A
- 750W power supply: 8.4 A
- 1100W power supply: 12 A
- 200-240 V:
- 550W power supply: 3.0 A
- 750W power supply: 4.1 A
- 1100W power supply: 6 A
- 100-127 V:
Electrical specifications for DC input power supply:
- Input voltage: -48 to -60 Vdc
- Inlet current (1100W power supply): 26 A
Operating environment
The ThinkSystem SR635 server complies with ASHRAE Class A2 specifications with most configurations, and depending on the hardware configuration, also complies with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.
The restrictions to ASHRAE A2 support are as follows:
- The use of a processor with a TDP of 225W or higher requires the ambient temperature be no more than 30°C
- The use of Two GPUs and a processor with a TDP higher than 120W requires the ambient temperature be no more than 30°C
- The use of Three GPUs requires the ambient temperature be no more than 30°C
- The use of Mid drive bays requires the ambient temperature be no more than 30°C
- The use of Rear drive bays requires the ambient temperature be no more than 30°C
- The use of Ethernet/InfiniBand adapters of 100Gb or 200Gb, combined with the use of a processor with a TDP of 180W or higher, requires the ambient temperature be no more than 30°C
To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements:
- Processor TDP greater than 155W not supported
- No support for 10x 2.5" front drive bays (the 4x 3.5-inch and 8x 2.5-inch bay configurations are supported)
- No support for NVMe drives
- No support for rear drive bays or mid drive bays
- No support for GPUs
- No support for M.2
- No support for PCIe flash storage adapters
- No support for OCP networking adapters of 10GbE or faster
- No support for Ethernet adapters of 10GbE or faster
- No support for DIMMs of 128GB or larger capacity
- Advanced heatsink (feature B5UR) and performance fans (feature B5X0) must be configured
Temperature and humidity
The server is supported in the following environment:
- Air temperature:
- Operating:
- ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
- Server off: 5°C to 45°C (41°F to 113°F)
- Shipment/storage: -40°C to 60°C (-40°F to 140°F)
- Operating:
- Maximum altitude: 3,050 m (10,000 ft)
- Relative Humidity (non-condensing):
- Operating
- ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
- ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
- ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
- Shipment/storage: 8% to 90%
- Operating
Heat output
The server generates the following heat:
- Heat/thermal output:
- Minimum configuration: 346 BTU/hr, 101 W
- Maximum configuration: 3197 BTU/hr, 937 W
Acoustical noise emissions
The server has the following acoustic noise emissions declaration:
- Sound power level (LWAd):
- Idling: 5.7 Bel (typical), 7.0 Bel (Storage rich), 7.0 Bel (GPU rich)
- Operating: 5.9 Bel (typical), 7.2 Bel (storage rich), 8.5 Bel (GPU rich)
- Sound pressure level (LpAm):
- Idling: 41 dBA (Typical), 54 dBA (Storage rich), 54 dBA (GPU rich)
- Operating: 43 dBA (Typical), 56 dBA (Storage rich), 69 dBA (GPU rich)
Notes:
- The sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.
- The declared acoustic sound levels are based on the following configurations, which may change slightly depending on configuration/conditions:
- Typical: 1x 155W CPU, 8x 32GB RDIMM, 8x 2.5" HDD, 530-8i RAID, X710-T2L OCP, 2x 750W PSU
- Storage rich: 1x 155W CPU, 16x 64GB RDIMM, 16x NVMe, 10GBASE-T 4-port PCIe Ethernet Adapter, 2x 750W PSU
- GPU rich: 1x 155W CPU, 16x 64GB RDIMM, 10x 2.5" HDD, 930-16i RAID, 10GBASE-T 4-port PCIe Ethernet Adapter, 2x T4 GPU, 2x 1100W PSU
Shock and vibration
The server has the following vibration and shock limits:
- Vibration:
- Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
- Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
- Shock:
- Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
- Non-operating:
- 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
Particulate contamination
Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might damage the system that might cause the system to malfunction or stop working altogether.
The following specifications indicate the limits of particulates that the system can tolerate:
- Reactive gases:
- The copper reactivity level shall be less than 200 Angstroms per month (Å/month)
- The silver reactivity level shall be less than 200 Å/month
- Airborne particulates:
- The room air should be continuously filtered with MERV 8 filters.
- Air entering a data center should be filtered with MERV 11 or preferably MERV 13 filters.
- The deliquescent relative humidity of the particulate contamination should be more than 60% RH
- Environment must be free of zinc whiskers
For additional information, see the Specifications section of the documentation for the server, available from the Lenovo Documents site, https://pubs.lenovo.com/
Warranty upgrades and post-warranty support
The SR635 has a 1-year or 3-year warranty based on the machine type of the system:
- 7Y98 - 1 year warranty
- 7Y99 - 3 year warranty
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The SR635 server conforms to the following standards:
- Energy Star 3.0
- FCC: Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 6, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
- IEC 60950-1 (CB Certificate and CB Test Report)
- China CCC (GB4943.1), GB9254 Class A, GB17625.1
- Taiwan BSMI CNS13438, Class A; CNS14336-1
- Korea KN32, Class A; KN35
- Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011(for Safety); TP TC 020/2011(for EMC)
- CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
- CISPR 32, Class A
- TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
- India BIS certification
External drive enclosures
The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.
Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com
Model | Description |
---|---|
4587HC1 | Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays) |
4587HC2 | Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays) |
6413HC1 | Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays) |
7DAHCTO1WW | Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays) |
For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:
- Lenovo Storage D1212 and D1224
http://lenovopress.lenovo.com/lp0512 - Lenovo Storage D3284
http://lenovopress.lenovo.com/lp0513 - Lenovo ThinkSystem D4390
https://lenovopress.lenovo.com/lp1681
External storage systems
Lenovo offers the ThinkSystem DE Series, ThinkSystem DG Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series, DG Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The server supports both USB-attached RDX backup units and SAS-attached tape drives.
The following table lists the available external SAS tape backup options.
Tip: Verify the end-to-end support of an IBM tape backup solution through the IBM System Storage Interoperation Center (SSIC): http://www.ibm.com/systems/support/storage/ssic
Part number | Description |
---|---|
External SAS tape backup drives | |
6160S6E | IBM TS2260 Tape Drive Model H6S |
6160S7E | IBM TS2270 Tape Drive Model H7S |
6160S8E | IBM TS2280 Tape Drive Model H8S |
6160S9E | IBM TS2290 Tape Drive Model H9S |
External SAS tape backup autoloaders | |
6171S6R | IBM TS2900 Tape Autoloader w/LTO6 HH SAS |
6171S7R | IBM TS2900 Tape Autoloader w/LTO7 HH SAS |
6171S8R | IBM TS2900 Tape Autoloader w/LTO8 HH SAS |
6171S9R | IBM TS2900 Tape Autoloader w/LTO9 HH SAS |
External tape backup libraries | |
6741A1F | IBM TS4300 3U Tape Library-Base Unit |
SAS backup drives for TS4300 Tape Library | |
01KP934 | LTO 6 HH SAS Drive |
01KP937 | LTO 7 HH SAS Drive |
01KP953 | LTO 8 HH SAS Drive |
02JH836 | LTO 9 HH SAS Drive |
For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
The following table lists the external RDX backup options available.
Part number | Feature code | Description |
---|---|---|
External RDX docks | ||
4T27A10725 | B32R | ThinkSystem RDX External USB 3.0 Dock (No cartridge included with the drive) |
Cartridges | ||
7TP7A01601 | AVF8 | ThinkSystem RDX 500GB Cartridge |
7TP7A01602 | AVF1 | ThinkSystem RDX 1TB Cartridge |
7TP7A01603 | AVF0 | ThinkSystem RDX 2TB Cartridge |
7TP7A04318 | AXD1 | ThinkSystem RDX 4TB Cartridge |
For more information, see the Lenovo RDX USB 3.0 Disk Backup Solution product guide:
https://lenovopress.com/tips0894-rdx-usb-30
Top-of-rack Ethernet switches
The following table lists the Ethernet LAN switches that are offered by Lenovo.
Part number | Description |
---|---|
1 Gb Ethernet Rack switches | |
7Y810011WW | Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) |
7Z320O11WW | Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) |
7159BAX | Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX | Lenovo RackSwitch G7052 (Rear to Front) |
7159G52 | Lenovo RackSwitch G8052 (Rear to Front) |
7165H1X | Juniper EX2300-C PoE Switch |
7165H2X | Juniper EX2300-24p PoE Switch |
1 Gb Ethernet Campus switches | |
7Z340011WW | Lenovo CE0128TB Switch (3-Year Warranty) |
7Z360011WW | Lenovo CE0128TB Switch (Limited Lifetime Warranty) |
7Z340012WW | Lenovo CE0128PB Switch (3-Year Warranty) |
7Z360012WW | Lenovo CE0128PB Switch (Limited Lifetime Warranty) |
7Z350021WW | Lenovo CE0152TB Switch (3-Year Warranty) |
7Z370021WW | Lenovo CE0152TB Switch (Limited Lifetime Warranty) |
7Z350022WW | Lenovo CE0152PB Switch (3-Year Warranty) |
7Z370022WW | Lenovo CE0152PB Switch (Limited Lifetime Warranty) |
10 Gb Ethernet switches | |
7159A1X | Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) |
7159B1X | Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) |
7Z330O11WW | Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) |
7159C1X | Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) |
7159CRW | Lenovo RackSwitch G8272 (Rear to Front) |
7159GR6 | Lenovo RackSwitch G8296 (Rear to Front) |
7159BR6 | Lenovo RackSwitch G8124E (Rear to Front) |
25 Gb Ethernet switches | |
7159E1X | Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) |
7Z210O21WW | Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) |
7Z330O21WW | Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) |
100 Gb Ethernet switches | |
7159D1X | Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) |
7Z210O11WW | Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) |
For more information, see the list of Product Guides in the following switch categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: http://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Fibre Channel SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | N | N | N | N | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | N | N | N | N | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU – CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 PDU+ | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | Enterprise C13 PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | Enterprise C19 PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | Enterprise C19 3 phase PDU (60a) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI 30amp/125V Front-end PDU with NEMA L5-30P | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI 30amp/250V Front-end PDU with NEMA L6-30P | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd connector | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd connector | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127v PDU with Fixed Nema L5-15P line cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | DPI 32a Cord (IEC 309 3P+N+G) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | DPI 32a Cord (IEC 309 P+N+G) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | DPI 63a Cord (IEC 309 P+N+G) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | DPI 30a Cord (NEMA L6-30P) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | DPI 60a Cord (IEC 309 2P+G) | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG to AS/NZS 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Rack cabinets
The following table lists the supported rack cabinets.
Model | Description |
---|---|
93072RX | 25U Standard Rack (1000mm) |
93072PX | 25U Static S2 Standard Rack (1000mm) |
7D6DA007WW | ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6DA008WW | ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA009WW | ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA00AWW | ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
1410O42 | Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet |
1410P42 | Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet |
1410O48 | Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet |
1410P48 | Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet |
93604PX | 42U 1200mm Deep Dynamic Rack |
93614PX | 42U 1200mm Deep Static Rack |
93634PX | 42U 1100mm Dynamic Rack |
93634EX | 42U 1100mm Dynamic Expansion Rack |
93074RX | 42U Standard Rack (1000mm) |
93084PX | 42U Enterprise Rack |
93084EX | 42U Enterprise Expansion Rack |
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
KVM console options
The following table lists the supported KVM consoles.
Part number | Description |
---|---|
Consoles | |
4XF7A84188 | ThinkSystem 18.5" LCD Console (with US English keyboard) |
4XF7A73009 | ThinkSystem 18.5" LCD console (with US English keyboard) |
17238BX | 1U 18.5" Standard Console (without keyboard - see the next table) |
The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).
Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.
Part number | Description |
---|---|
7ZB7A05469 | ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2 |
7ZB7A05468 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2 |
7ZB7A05206 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2 |
7ZB7A05207 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2 |
7ZB7A05208 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2 |
7ZB7A05210 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2 |
7ZB7A05209 | ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2 |
7ZB7A05211 | ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2 |
7ZB7A05212 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2 |
7ZB7A05213 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2 |
7ZB7A05214 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2 |
7ZB7A05215 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2 |
7ZB7A05216 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2 |
7ZB7A05217 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2 |
7ZB7A05218 | ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2 |
7ZB7A05219 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2 |
7ZB7A05220 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2 |
7ZB7A05221 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2 |
7ZB7A05222 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2 |
7ZB7A05223 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2 |
7ZB7A05231 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2 |
7ZB7A05224 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2 |
7ZB7A05225 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2 |
7ZB7A05226 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2 |
7ZB7A05227 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2 |
7ZB7A05467 | ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2 |
7ZB7A05228 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2 |
7ZB7A05229 | ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2 |
7ZB7A05470 | ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2 |
7ZB7A05230 | ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2 |
The following table lists the available KVM switches and the options that are supported with them.
Part number | Description |
---|---|
KVM Console switches | |
1754D1T | ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port) |
1754A1T | ThinkSystem Analog 1x8 KVM Switch (DVI video output port) |
1754D2X | Global 4x2x32 Console Manager (GCM32) |
1754D1X | Global 2x2x16 Console Manager (GCM16) |
1754A2X | Local 2x16 Console Manager (LCM16) |
1754A1X | Local 1x8 Console Manager (LCM8) |
Cables for ThinkSystem Digital and Analog KVM Console switches | |
4X97A11108 | ThinkSystem VGA to DVI Conversion Cable |
4X97A11109 | ThinkSystem Single-USB Conversion Cable for Digital KVM |
4X97A11107 | ThinkSystem Dual-USB Conversion Cable for Digital KVM |
4X97A11106 | ThinkSystem USB Conversion Cable for Analog KVM |
Cables for GCM and LCM Console switches | |
43V6147 | Single Cable USB Conversion Option (UCO) |
39M2895 | USB Conversion Option Pack |
46M5383 | Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 | Serial Conversion Option (SCO) |
For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Seller training courses
The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.
-
Family Portfolio: Storage Controller Options
2025-03-03 | 25 minutes | Employees and Partners
DetailsFamily Portfolio: Storage Controller OptionsThis course covers the storage controller options available for use in Lenovo servers. The classes of storage controller are discussed, along with a discussion of where they are used, and which to choose.
Published: 2025-03-03
After completing this course, you will be able to:
• Describe the classes of storage controllers
• Discuss where each controller class is used
• Describe the available options in each controller class
Length: 25 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
ThinkSystem Rack and Tower Introduction for ISO Client Managers
2024-12-10 | 20 minutes | Employees Only
DetailsThinkSystem Rack and Tower Introduction for ISO Client ManagersIn this course, you will learn about Lenovo’s Data Center Portfolio, its ThinkSystem Family and the key features of the Rack and Tower servers. It will equip you with foundational knowledge which you can then expand upon by participating in the facilitated session of the curriculum.
Published: 2024-12-10
Course Objectives:
• By the end of this course, you should be able to:
• Identify Lenovo’s main data center brands.
• Describe the key components of the ThinkSystem Family servers.
• Differentiate between the Rack and Tower servers of the ThinkSystem Family.
• Understand the value Rack and Tower servers can provide to customers.
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo -
Partner Technical Webinar - Server Update with Mark Bica
2024-11-26 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - Server Update with Mark BicaIn this 60-minute replay, Mark Bica, Lenovo Product Manager gave an update on the server portfolio. Mark presented on the new V4 Intel servers with Xeon 6 CPUs. He reviewed where the new AMD 5th Gen EPYC CPUs will be used in our servers. He followed with a review of the GPU dense servers including SR680, SR680a, SR575 and SR780a. Mark concluded with a review of the SC777 and SC750 that were introduced at TechWorld.
Published: 2024-11-26
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Family Portfolio: ThinkSystem Rackmount and Tower Servers powered by AMD
2024-11-25 | 30 minutes | Employees and Partners
DetailsFamily Portfolio: ThinkSystem Rackmount and Tower Servers powered by AMDThis course presents the key products and features of the ThinkSystem Rackmount and Tower server family powered by AMD processors. It describes customer benefits and will help you recognize when a specific product should be selected.
Published: 2024-11-25
Course Objectives:
By the end of this course, you should be able to:
• Identify products and features within the family
• Describe customer benefits offered by this family
• Recognize when a specific product should be selected
Length: 30 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Partner Technical Webinar - LenovoPress updates and LPH Demo
2024-11-13 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - LenovoPress updates and LPH DemoIn this 60-minute replay, we had 3 topics. First, David Watts, Lenovo Sr Manager LenovoPress, gave an update on LenovoPress and improvements to finding Seller Training Courses (both partner and Lenovo). Next, Ryan Tuttle, Lenovo LETS Solution Architect, gave a demo of Lenovo Partner Hub (LPH) including how to find replays of Partner Webinars in LPL. Finally, Joe Murphy, Lenovo Sr Manager of LETS NA, gave a quick update on the new Stackable Warranty Options in DCSC.
Published: 2024-11-13
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Virtual Facilitated Session - ThinkSystem Rack and Tower Primer for ISO Client Managers
2024-10-31 | 90 minutes | Employees Only
DetailsVirtual Facilitated Session - ThinkSystem Rack and Tower Primer for ISO Client ManagersIn this Virtual Instructor-Led Training Session, ISO Client Managers will be able to build on the knowledge gained in Module 1 (eLearning) of the ThinkSystem Rack and Tower Server Primer for ISO Client Managers curriculum.
Published: 2024-10-31
<p>
<span style="color:red; font-weight:bold;"> IMPORTANT! </span> <span style="font-weight:bold;"> Module 1 (eLearning) must be completed to be eligible to participate in this session. Please note that places are subject to availability. If you are selected, you will receive the invite to this session via email. </span>
</p>
Length: 90 minutesStart the training:
Employee link: Grow@Lenovo -
Partner Technical Webinar - OneIQ
2024-07-15 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - OneIQIn this 60-minute replay, Peter Grant, Field CTO for OneIQ, reviewed and demo’d the capabilities of OneIQ including collecting data and analyzing. Additionally, Peter and the team discussed how specific partners (those with NA Channel SA coverage) will get direct access to OneIQ and other partners can get access to OneIQ via Distribution or the NA LETS team.
Published: 2024-07-15
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
SAP Webinar for Lenovo Sellers: Lenovo Portfolio Update for SAP Landscapes
2024-06-04 | 60 minutes | Employees Only
DetailsSAP Webinar for Lenovo Sellers: Lenovo Portfolio Update for SAP LandscapesJoin Mark Kelly, Advisory IT Architect with the Lenovo Global SAP Center of Competence as he discusses:
Published: 2024-06-04
• Challenges in the SAP environment
• Lenovo On-premise Solutions for SAP
• Lenovo support resources for SAP solutions
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo -
Lenovo Data Center Product Portfolio
2024-05-29 | 20 minutes | Employees and Partners
DetailsLenovo Data Center Product PortfolioThis course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.
Published: 2024-05-29
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
VTT Cloud Architecture: NVIDIA Using Cloud for GPUs and AI
2024-05-22 | 60 minutes | Employees Only
DetailsVTT Cloud Architecture: NVIDIA Using Cloud for GPUs and AIJoin JD Dupont, NVIDIA Head of Americas Sales, Lenovo partnership and Veer Mehta, NVIDIA Solution Architect on an interactive discussion about cloud to edge, designing cloud Solutions with NVIDIA GPUs and minimizing private\hybrid cloud OPEX with GPUs. Discover how you can use what is done at big public cloud providers for your customers. We will also walk through use cases and see a demo you can use to help your customers.
Published: 2024-05-22
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo -
Partner Technical Webinar - ISG Portfolio Update
2024-04-15 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - ISG Portfolio UpdateIn this 60-minute replay, Mark Bica, NA ISG Server Product Manager reviewed the Lenovo ISG portfolio. He covered new editions such as the SR680a \ SR685a, dense servers, and options that are strategic for any workload.
Published: 2024-04-15
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Partner Technical Webinar - StorMagic
2024-03-19 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - StorMagicMarch 08, 2024 – In this 60-minute replay, Stuart Campbell and Wes Ganeko of StorMagic joined us and provided an overview of StorMagic on Lenovo. They also demonstrated the interface while sharing some interesting use cases.
Published: 2024-03-19
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Lenovo-Intel Sustainable Solutions QH
2024-01-22 | 10 minutes | Employees and Partners
DetailsLenovo-Intel Sustainable Solutions QHThis Quick Hit explains how Lenovo and Intel are committed to sustainability, and introduces the Lenovo-Intel joint sustainability campaign. You will learn how to use this campaign to show customers what that level of commitment entails, how to use the campaign's unsolicited proposal approach, and how to use the campaign as a conversation starter which may lead to increased sales.
Published: 2024-01-22
Length: 10 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Family Introduction: Rack and Tower
2024-01-19 | 11 minutes | Employees and Partners
DetailsFamily Introduction: Rack and TowerThis course is designed to give Lenovo sales and partner representatives a foundation on the characteristics of the rack and tower server family. As an introduction to the family, this course also includes positioning, when to use a product, and keywords a client may use when discussing a rack product.
Published: 2024-01-19
Course Objectives:
• Family Characteristics
• Priority Positioning
• Product Usage
• Keywords and Phrases
Length: 11 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
ServerProven®
System x®
ThinkAgile®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
AMD and AMD EPYC™ are trademarks of Advanced Micro Devices, Inc.
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, ActiveX®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
SPECpower® is a trademark of the Standard Performance Evaluation Corporation (SPEC).
Other company, product, or service names may be trademarks or service marks of others.